Can all intrinsic safe transmitters are provided with
inbuilt zener barriers? why

Answers were Sorted based on User's Feedback



Can all intrinsic safe transmitters are provided with inbuilt zener barriers? why..

Answer / amit patil

YES ALL INTYRENSIC SAFE TRANSMITTERS R BOUNDED WITH ZENSER
BARRIERS BECAUSE THESE R HAZARDOUS SIGNALS COMMING FROM THE
FIELD, SO TO AVOID ANY DANGEROUS EFFECT TOWARDS THE PANNEL
SIDE BARRIERS R USED THESE R SO THAT IF MORE CURRENT IS
COMMING FROM YHE FIELD THEN THE BARRIER BECOMES OPENE TO B
SAFE FOR PANEL SIDE.

Is This Answer Correct ?    9 Yes 1 No

Can all intrinsic safe transmitters are provided with inbuilt zener barriers? why..

Answer / suresh

For safety of DCS input card. Possibility for short circuit or high current came from field so berrirer working as fuse it will get open so current not pass to card.because card

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Instrumentation Interview Questions

what is control valve and how is work

5 Answers   Descon,


how i can copy paste the program of smart transmitter to another smart one with hart communicator?

2 Answers   KOC,


I want to measure and control level in tank of size 10*5 filled with gasoline, so plz give me the solution with clear details. how to select transmitter and sensors.

0 Answers  


How RAL(Rotary air lock)works in cement industry?

0 Answers   Jaypee,


How find CGPA? when marks are 515/850 & 2559/3350. Plz any one tell me.

1 Answers  






What is the role of P(Protional), I(Integral) and D (Derivative) in PID Controller?

9 Answers  


How will you calibrate an Absolute Pr.Transmitter of range 400mmHg absolute ?

0 Answers   CCIE,


How does a strain gauge measure pressure?

2 Answers  


what is intrument termination what is commisioning

3 Answers  


what is difference between two wire &three wire pt 100 ?

3 Answers   Jindal,


what is the diffrence between pressure safety valve & pressure relief valve....pls

0 Answers   Oil India,


warning lamp does not light, but it does light when the wire from the lamp going to the sending unit is grounded (the part that plugs into the sending unit) what does this indicate)?

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5084)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)