hey guys i recently saw a long transmission line in which a
sort of balloons in red and white color were hanging at each
section.do u have any idea why are they kept for?
Answers were Sorted based on User's Feedback
Answer / eweph
Its purpose is mainly for aircraft warning device as cables is hardly visible for the aircraft.
| Is This Answer Correct ? | 7 Yes | 2 No |
Answer / ashish
during the maintenance of xmission line this sort of tech
is used. in this way red ballon are placed over that
section which may b in any possible way may be faulty and
results u static charge. thus this provide information to
the person who is maintaining the cable that which region
is hazardeous.
| Is This Answer Correct ? | 2 Yes | 2 No |
Answer / charu
ya they are indication to flying planes, helicopters etc ythat transmission lines are present. because lines are not visible from aircrafts and they can and have faced accident in the past
http://while-working.blogspot.com
http://electrical-engineering-tutorials.blogspot.com
| Is This Answer Correct ? | 1 Yes | 1 No |
calculation of lad carryinc capacity of 6mm2 cross section wire in 415 voltage circuit. What will be the amps.
What is dc current source?
Can Induction motor run at over rated speed? ( 15oo rpm is rated speed for 50HZ. is it possible to ride 3000 RPM with same motor with the help of VVVFD for continues ride of 100HZ)
when we have to purchase the transformer by own i.e how much load will preferred HT connection?
A 60w bulb & a room heater are connected in series.if 60 w bulb is replaced by 100w then what will be the effect on heater out & why?
what is XLPE type cable
What is the comparision (advantages / disadvantages) of 110V, 60 Hz system to 230 V, 50 Hz system.
I want to know the currect formula for industrial lighting lux caluculation & light fittings selection
why we are grounding the neutral?
how would you determin the horsepower of a motor without a nameplate
HOW TO CHECK THE VECTOR GROUP OF A TRANSFORMER YD11?
We have one 500KVA transformer. We have tested REF relay and commissioned. After one and half year, due to some ground fault in one of the DB circuit Transformer tripped by REF relay. What will be cause and remedy. Please advise?
Civil Engineering (5086)
Mechanical Engineering (4453)
Electrical Engineering (16638)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)