We are having proplem with the persperation smell in
ETT/ECHO room in our cardiac hospital.The 2 Ton of AC is
not conditioning the environment. We have to use exhaust
fan to through out of the room bad air. Could anyone
suggest how to coup with this effectively using chemical
engineering. Any permanent solution to neutralise the bad
smell.The Air freshners are not doing enough instead making
a bad odour.
No Answer is Posted For this Question
Be the First to Post Answer
hai i A neelakanteswara rao ,selected for the interview on 15th july 2008. I completed my diploma in chemical engineering.let me know how to face the interview& the type of technical questions.
please send me Ongc Exam Previous Papers... To MU MAil Id: muyyaboina.kalyani@gmail.com
how will we calculate the heat of formation through electron...??
which reformer efficiencywise best?
What is formula for petrol?
Explain what type of pump may be appropriate for a liquid near saturation, a low flow rate, and very limited npsha (net positive suction head available)?
Define an additive?
ACCOUNTING AND FINANCIAL ENGINEERING - EXAMPLE 34.31 : In a biochemical engineering company, let the actual revenue generated = A, actual cost incurred = B. According to the standard budget, the revenue generated = C, cost incurred = D. (a) Find the profit according to : (i) actual situation; (ii) standard budget. (b) Calculate the Variance Due to Price and Efficiency in : (i) revenue generated; (ii) cost incurred; (iii) profit. (c) If E > F where > represents : more than, find the 4 pairs of values of E and F in favorable conditions.
QUANTUM COMPUTING - EXAMPLE 32.5 : In quantum teleportation, let (C0 + D1) (00 + 11) = C000 + C011 + D100 + D111. Ba = 00 + 11, Bc = 10 + 01, Be = 00 - 11, Bm = 10 - 01. (a) Find the values of 00, 01, 10 and 11 in term of Ba, Bc, Be and Bm. (b) Prove by calculation that (C0 + D1) (00 + 11) = 0.5 [ Ba (C0 + D1) + Bc (C1 + D0) + Be (C0 - D1) + Bm (-C1 + D0) ].
Explain the common failure mechanism for above ground atmospheric storage tanks?
What is difference between overall heat transfer coefficient & individual heat transfer coefficient?
Question 69 - A well delivers 225 US-gallons per minute of water to a chemical plant during normal system operation. (a) Calculate its flowrate in the unit of mega US-gallon per day or MGD. (b) The following formula is written next to the chlorine feed point : (chlorine feed rate, lb / day) = (flowrate, MGD) X (dose, mg / L) x (8.34). If this formula is correct, then what should the chlorine feed rate to be in pounds per day (lb / day) if the desired dose is 2 mg / L. (c) Prove by calculations that the constant 8.34 in the formula next to the chlorine feed point is correct. Let 1 US-gallon = 3.78541 L and 1 mg = 0.0000022046 pound.