What is the largest application for surfactants?
No Answer is Posted For this Question
Be the First to Post Answer
At what temperature is glass fused to steel in the making of glass-lined equipment?
ACCOUNTING AND FINANCIAL ENGINEERING - EXAMPLE 34.29 : An engineering company that produces small biochemical tools applies Installment Sales Method in its accounting. Let A = Installment Sales, B = Cost of Installment Sales, C = Gross Profit, D = Gross Profit Ratio. In year 20X8, let A = $400, B = $250, C = $150. In year 20X9, let A = $450, B = $315, C = $135. If the value of D = 37.5 % in year 20X8 : (a) find the value of D for year 20X9; (b) calculate the realized gross profit = ED / 100, for year 20X8 when the cash collected from sales is E = $100.
Is there a rule of thumb to estimate the footprint of a cooling tower during design phase?
How to caliculate the boil up rate, dia and height in both packed and tray distillation columns and any referance books for the design.
sir i am appearing in railway exam of section engineer and my branch is chemical engineering i want previous question paper of section engineer of chemical branch please tell me as soon as possible my email id is surendrasaroj18@gmail.com THANKYOU
marketing procedure of iocl
For a Vernier scale of representative fraction (RF) = 1 / 25, calculate the length of the scale for the reading up to 4 metres.
What is quicklime and what are the uses?
We are having proplem with the persperation smell in ETT/ECHO room in our cardiac hospital.The 2 Ton of AC is not conditioning the environment. We have to use exhaust fan to through out of the room bad air. Could anyone suggest how to coup with this effectively using chemical engineering. Any permanent solution to neutralise the bad smell.The Air freshners are not doing enough instead making a bad odour.
what is factories act?tell about factories act?
hello everyone do anyone have interview questions for any chemical industry please email me at ravijallu.nitj@gmail.com
NATURAL GAS ENGINEERING - QUESTION 26.1 : (a) In natural gas pipe sizing, the length of the pipe from the gas source metre to the farthest appliances is 60 feet. The maximum capacities for typical metallic pipes of 60 feet in length are : 66 cubic feet per hour for pipe size of 0.5 inches; 138 cubic feet per hour for pipe size of 0.75 inches; 260 cubic feet per hour for pipe size of 1 inch. By using the longest run method : (i) Find the best pipe size needed for the capacity of 75 cubic feet per hour. (ii) Estimate the suitable range of capacities for the pipe size of 1 inch. (b) The maximum capacities for typical metallic pipes of 50 feet in length are : 73 cubic feet per hour for pipe size of 0.5 inches; 151 cubic feet per hour for pipe size of 0.75 inches; 285 cubic feet per hour for pipe size of 1 inch. By using the branch method find the best pipe size needed for the capacity of 75 cubic feet per hour when the length of the pipe from the gas source metre to the appliance is 52 feet.
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)