how to consider the laping length of steel?
Answers were Sorted based on User's Feedback
Answer / kailash solanki
Generally we take 50times dia. of Bars.
Is This Answer Correct ? | 16 Yes | 3 No |
Answer / ajeet kumar bhatnagar
lapping length considered on type of steel and grade of
concrete. for example if using mild steel and m20 grade
concrete then lap lenth will be more in comparision of tor
HYSD steel fe500 and m40grade concrete.
Is This Answer Correct ? | 7 Yes | 4 No |
Answer / suresh
as per is code we keep 38d to 50d otherwise as per drawing
Is This Answer Correct ? | 5 Yes | 2 No |
Answer / brajesh kaurav
as per IS 456-2000(for concret structure)code minimum
laplength should be consider is 36d very d is greter dia.of
bar.and also laps will always be Staggered in
height/placement so to say all lapses will not be at one
position/placement.
Is This Answer Correct ? | 3 Yes | 1 No |
Answer / muthu krishnan
It considered only depends upon the grade of steel and
tensile strength of the steel.
Is This Answer Correct ? | 2 Yes | 1 No |
Answer / r.saleemabegum
laplenth 50 times the diameter of the bar.
Is This Answer Correct ? | 2 Yes | 2 No |
Q 1) 1 Mason and 2 LABOUR / _________CUM brick work Q 2) 1 Mason and 1 LABOUR / _________SQ FT Plaster work Q 3) 1 Carpenter & 2 Labour/_________SQ FT shuttering work Q 4) 100 SQ FT roof slab concreting ____________mason and labour required
what is the difference between onw way slab & two way slab?
Laboratory experiments conducted in Mumbai on a particular mix showed a strength of 33 MP a for a fully matured concrete. Find whether formworm can be removed for an identical concrete placed at Jammu at the age of 15 days when the average temperature is 60C. The stripping stress in concrete
How can we find out the clear cover for a circular ring and rectangular ring..
What is HEAVIER? A kilo of SAND OR A kilo of GRAVEL?
What are the structural steel & where they are used
How much the quantity of Dry material of Crush for 1:2:4 Concrete, using pan 3/8'' down....
why we use min. 12mm dia bar in a coloum.
7 Answers BPCL Bharat Petroleum,
Cut Linten (RCC-1:2:4)on 10" wall - what should be the width and hight of cut Linten? Secondly, 1 X 1.6 foot,4" thick window sun/rain shed (Chajja)should consume steel,Cement, sand and Stone chips?
Deshuttering time for slab 6.15 meter
how to take quantity of steel per cum in columns
2 Answers ERRA, Skyline Builders,
Providing and fixing in position Tor steel to footings, foundation, slabs, beams, columns, canopies, stair case, newels, chajjas, lintels, etc. including cutting, bending, hooking the bars, binding with wires. give me the rate M.ton.