HOW TO CALCULATE WAKE FREQUENCY FOR THERMOWELL???WITH OUT
SOFTWARE..
Answer / gk3000
wake frequency
Fw = 2.64 x Fluid velocity(feet/sec) / Dia. of well tip
(inch).
Refer to ASME PTC 19.3
| Is This Answer Correct ? | 14 Yes | 2 No |
what is difference between venturi and orifice
Can anyone say that formula of Converting the Diff. Pressure into Flow in Kg/Cm2 or any explaniation of Orifice Plate, Beta Ratio , How to calculate
how the actually positioner of control valve working? where we gave 3-15psi pressure to I/P converter where it is firstly applied ?- on I/P to positioner then what happen? is control valve operate on 3-15 psi or its bench pressure?
why we are using boosters at glass furnace is there any other thing?
State four different types of flow measurement, for gas flow measurement MMSCFD is the common unit expand the unit and specify significance of word S in the unit.
Draw a 3 element level control loop and explain
pls give me presant awerness quistion and answer in my emailid.
suppose in dcs range of a flow transmitter is 10t/hr what is dp for 50% in 2500mmwc
Lube oil pressure transmitter local it's showing 9.8 kg/cm2 but dcs side it's showing 9.26 like that what is the reason?
what is the difference between cold loop and hot loop
why k factor is important to know in flow transmitter. if we don,t know k factor what will be issue we can face .
1 Answers Flour Tech Engineers (P) Ltd,
1 How to calculate dp transmitter steam and water? 2 impulse line for liquid steam and gas
1 Answers Sitara Chemical Industries,
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)