What is the minimum compressive strength of a brick according to IS codes ?
Answers were Sorted based on User's Feedback
Answer / sachin pawar
the min. compressive strength of bricks is 3.5 n/mm2
sachin
BLA POWER
| Is This Answer Correct ? | 8 Yes | 4 No |
Answer / mohsin ahemad
Compressive /Crushing strength of bricks (Indian Made) are very variable, and may vary from 30 kg/sq. cm to 150 kg/sq. cm for hand-made burnt bricks, while Crushing strength of heavy duty bricks machine pressed (also called engineering bricks) may have compressive strength as high as 450kg/sq. cm, and even 500 kg/sq. cm. The minimum crushing / compressive strengths of burnt bricks tested flat-wise prescribed are:
(i) Common building bricks—35 kg/sq. cm,
(ii) Second class bricks—70 kg/sq. cm,
(iii) First class bricks— 105 kg/sq. cm.
(iv) Crushing strength of bricks not less than 140 kg/sq. cm are graded as AA class.
The strength of bricks decreases by about 25 per cent when soaked in water.
Strength of sun-dried (unburnt) bricks is from 15 to 25 kg/sq. cm.
Water absorption of bricks after 24 hours immersion,
First class bricks—20%,
Second class bricks—22 %,
Third class bricks—25%.
Heavy duty machine made bricks should not absorb more than 5% of their weight.
| Is This Answer Correct ? | 4 Yes | 1 No |
Answer / amol kalokhe
Min.compressive strength of a birck is 3.5N/mm2
It depends upon the class of brick we are using.
please refer IS 1077 clause 4.1,page no.1
| Is This Answer Correct ? | 3 Yes | 1 No |
Answer / sakal
as per Is:2512 Part II
Min . Requirement Is 5 Mpa in aveg.
& 4 Mpa in Individual.
| Is This Answer Correct ? | 3 Yes | 3 No |
Answer / shailendra dubey
As per IS:1077, The min. compressive strength when tested
flat shall not be less than 8.4MPa for individual bricks
and 10.5MPa for average of 5 specimens.
| Is This Answer Correct ? | 3 Yes | 3 No |
Answer / raju nayak telangana
3.5Mpa as per IS CODE is minimum compressive strength of bricks in case of dry state
| Is This Answer Correct ? | 1 Yes | 1 No |
Answer / aman
3.5 n/sq mm. minimam compressive strengthbn of bricks
| Is This Answer Correct ? | 0 Yes | 0 No |
What letter follows after these, O, T, T, F, F, S, S, E, __?
what is the meaning for 'prime cost' in civil construction contracts?
3 Answers EPPPL, Nagarjuna Construction,
how much brick,cement,and sand required in 1cum brickwork(1:4)
which beam has more strength rectangular or circular
Method of findingthe dry ingredient quantity of 1 m3 concrete.
25 Answers Annai Infra Developers, GKC Projects Limited GKCPL, IRE, L&T, Mahle Filter Systems, NCC, PNRD, Rama, RCC, Shivani Agriculture, Sobha Developers, Suraj Constructions, TCL,
What is the diff between cad & cadd?
for pretensioning which will yield first and same for post tensioning?
What is the benefit of making a cantiliver proped.?
7 Answers CCCL, Engineers India Limited,
Can we use Polystyrene as a Bitumen modifier !! if so is it a good MS research topic ? and what type of laboratory tests will be conducted during Research work ??
a g+2 building having mezenine floor ,but stair is approching only 1st and 2nd floor, in this case stair is calculate in plinth area for mezenin floor or not?
what are the challenges of being a team leader and a supervisor?
How many stones require for 1200 Sq ft house
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)