What is the normal earth resistance?

11 26833

WHAT IS THE WINDING PROCEDURE OF ELECTRICAL MOTOR

GE,

3460

what is SWA type of cable?????

4 7239

I have 11KV/415V power distribution transformer. I have found unbalance current in LT (415V) side. Also observed that unbalance voltage (3V) at LV side due to HV side unbalance voltage. What should I check for this? Also, the same LV side load can run in balance on captive power.

1 4411

What is the function of automatic Transfer Switch(ATS) in details

3 23973

Why Delta Star Transformers are used for Lighting Loads.

6 25266

What is the basic principal, by which DC voltage level is increased more than the supplied AC voltage during conversion. As upto AC level it is contorrled by firing anlge but after maximum level how is it possible.Please clear picture. OR we have to supply the higher level AC?

1407

Define the overload capacity of the motor?

1519

Why is starter necessary for a three-phase induction motor?

BMM, Essar, Hero MotoCorp, ITI, Maruti Suzuki, Supertech, Watt,

37 166911

What is the need of motor starter?

6 10824

What are the advantages of star-delta starter with induction motor?

Merchant Navy, Naval Academy, Samundra Institute of Maritime Studies, YMCA,

7 43791

What are the advantages of DOL starter?

7 36013

Why is the starting current high in a DC motor?

2 11086

How will you determine the rating of a motor for continuous duty variable load motor applications?

1 3488

Enlist four components of electrive drives.

1359


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

what do u understand from filter factor of reactor?

1473


WHAT IS SITTING AMPS IN OVER-LOAD RELAY FOR 1PH OR 3PH MOTORS?IF ITS NAME PLATE GIVEN MAX AMPS 10AMPS?

1282


How to back charge the Gas turbine generator

1551


what is KA rating and how can we choose switchgears on applications

903


What type of wiring series or parallel is used for conventional and addressable type FAS & why?

1300






75 kw motor take 45 amp in no load delta in star 10 amp but in load it will take 160 amp but IR velue of winding above 500 at 1kw ph to earth and ph to ph. what problem it should be?

3194


kVA rating of ordinary transformer is increased when connected as an auto transformer because A transformation ratio increased B secondary voltage increased C energy is transferred both inductively and conductively D secondary current increased

2070


List of equipments required foe industrial repair lab.

1430


What are your future plans for the company if permanently employed?

1608


PIU how does work?

1902


EXPLAIN WHY THE SURGE CURRENT RATING OF AN MCCB OR CIRCUIT BREAKER DECREASES WITH INCREASE IN THE RATING OF MCCB OR CIRCUIT BREAKER.

1461


What are the difference between normal application Transformer and Solar application Transformer?

1176


What happen when change order of CT in GIS feeder?

1055


.php|

1649


why we take movement of rotor always in counter-clockwise direction in 3-phase induction motors?

1432