Electrical Engineering Interview Questions
Questions Answers Views Company eMail

IN THE CASE OF AN ELCB, IF THERE IS ANY UNSTABILITY BETWEEN PHASE AND NEUTRAL IT MAY TRIP. BUT MY QUESTION IS WHEN A LOAD IS CONNECTED IN BETWEEN P AND N, THE LOAD CONSUMES SOME POWER AND THERE IS A DIFFERENCE IN NEUTRAL WITH RESPECT TO THE PHASE. THUS ACCORDING TO ME, THE ELCB WILL AUTOMATICALLY OPERATES WHEN EVER THE LOAD CONSUMES-- I KNOW IT IS WRONG. BUT THE SOLUTION IS?????????

KSEB,

1 3414

while we select CT, why the CT ratio is divided by 5?? ex:250/5,15VA,CLASS-1 CT.Why it is divided by 5??Help me please

2 4140

Capacitor panel CT is normally fixed on Y phase of the main panel.why???

3 7797

what is the step by step formula for calculating bus bar phase and neutral size of a panel board.suppose the incomer of panel board is 100A..???step by step answer please

1 2963

what is the function of capacitor duty contactor in an capacitor panel???

3607

What should be the overcurrent, instantaneous overcurrent, short cicuit current settings (i.e. how many times of motor full load and what is the time duration) for a motor?

1 2136

12.5 KVAR capacitor 440V gas filled, Its used for windmill purpose, How can i know about microfarad value for this capacitor

2 3961

I know the Capacitor value- 12.5KVAR, voltage 440V gas filled, then what is the formula for calculate the microfarad value for this 12.5KVAR capacitor

2 3337

can i use 2000/5A Clamp meter to measure HT cable

century, Engro,

1559

WE HAVE A PROBLEM THAT THE MAIN DRIVE OF OUR CEMENT MILL HAS AN EARTHING PROBLEM?TWO OF STATOR WINDINGS INSULATION HAS BEEN COLLAPSED DUE TO AGING PROBLEM.THE PHASES HAVE BEEN BYPASSED AND NOW THE LOAD HAS BEEN INCREASED.WE CAN'T REPLACE THE MOTOR.KINDLY HELP ME BY GIVING SUGGESTION THAT HOW TO MAINTAIN THE STARTING TORQUE AND CURRENT FOR HIGH LOADS.

ACC,

1 3197

RATING OF LIGHTENING ARRESTER FOR 11 KV LINE IS 9 KV is ok ,but haw to calculate the KA rating?

1525

Kindly give the brief explanations for checking 12.5 kvar 440V, 25 KVAR 440V, 12.5KVAR 690V, 25 KVAR 690V capacitors microfarad values. what is the microfarad values for the above four type of capacitors, and give the formula explanations briefly. I know F-50HZ, voltage, and capacitor.

1 4045

why any normal motor have to provide star & delta winding distribution during starting?

4 4059

Why phase sequence must be same in any ht motor or generator circuit?if phase sequence doesn't same whatever will be affect on circuit?

1713

what is meant by neutral compensation factor and where it is used

1441


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

How to calculate Ith (I thermal) for curent transformer

1558


State uses of different types of stsrters with different capacities of motors as below: a. up to 5HP b. above 5hp to 10hp c. above 10hp to 20hp d. above 20hp

1464


what is the need of starter in tube light and what type of starter is used in that?

1509


Why power factor should not be in leading (capacitive) mode of any load.

5835


Where should the lighting arrestor be placed in distribution lines?

660






What is the relation between frequency and motor rpm?

1326


What is the difference IN MCCB's between thermal magnetic and electronic tripping system ?

1536


How can i get my certificate of competency as an electrical supervisor? I have complicated my B.Tech from Uttarakhand technical university this year (2012).

3990


What is the size of a 60 watt and 80 watt tubelight?

1744


can any one know is sbi interview based on merit or based on roll number

1492


1. What is maximum permissible distance between smoke detectors ? 2. How do we decide number of smoke detectors required in a large office, warehouse, hall etc ? 3. What should be maximum height of smoke detectors ? 4. Where do we use heat detector, optical smoke detector, temperature sensitive detector ?

2372


In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.

1121


What is icu and ics in Acb and how many time icu or ics passes from breaker?

1040


If Polarization index of motor 8.75 at 500volts of medium voltage 4.16 KV motor what this mean winding good or bad pl answer if any reffrence book give me the link

1715


HI SIR, AM PREPARING FOR RRB FOR SECTION ENGINEER POST. PLZ SEND ME THE PREVIOUS QUESTION PAPERS AND HELP ME. I HAVE NO ENOUGH TIME MY EXAM DATE IS 22ND JUNE.... MY EMAIL ID IS nalla.amarnath@gmail.com