Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

why AC voltage source are generate as 50 Hz ?

4 6766

What will happen if induction motor is supplied with capacitive load?

NTPC,

1 5471

how we identify between current transformer and potential transformer without having it name plate?

L&T, TATA,

5 13022

Please give the formula for converting from 1 tr refrigeration to kw.

Bugema University,

2 4715

what is settable hystersis protection? If any body knows plz kindly post the answer..

2103

what is the formula for computing cable tray size & capacity

2214

what clearance required for 4.5 mva dry type transformer?

SPS,

2075

how to calculate lighting for a room

Coca Cola,

2 7786

How can we select suitable capacity generator for three phase load (inductive load) and how to take study analysis in 3 three phase load system ?

2186

A group of machines (wind turbines) connected with 33KV feeder and each machines are having individual VCB. The 33KV feeder connected with 110KV/33KV substation. The 33KV feeder tripped by over current at Substation and fault recorded at Substation as OC-R&Y phase. Same time the group of machines VCB tripped by over voltage, the fault recorded voltage was above 66KV by numerical Under/Over voltage relay. While grid drop time, this much of voltage hike is possible?

1 3473

method to check earthing

ECC,

5 12051

why slipring motor , at full speed run as squirrel cage motor?

1 4204

I have running 4 generator in paralel.All generators Voltages is same(470 V),KW also same (100 KW) but only No2 generator Amper is high than another generators. DG No:1,3,4 470V,100KW, 150 A DG No:2 470V,100KW,400 A

4 5773

What is the permissible value of earth resistance and as per which standard / act / rule ?

HBL Power Systems,

3 7216

The loads are connected with phase and ground then why current flow as the loads ?

2011


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

which protection function should measure RMS value of current&DFT value of current?

2135


Why are the laminations insulated from each other?

1213


What type interview questions ask in Electrical technicians

1869


I Just want do EHS Certified Certification Distance Course From Govt approved,so can any body provide me details.

2180


Write down the brushes of a de machine.

1935


why dc is used in control circuit for mv & hv switchgear instead of ac

1968


A system absorbs 100 k J of heat and the increase in its internal energy is 100 kJ; the work done is

1333


What is domestic transformer? Draw the connection of domestic transformer.

2357


Is there a possibility to use such a treshold voltage for the NMOS part of a CMOS circuit that during the switching it will start conducting only after the PMOS part will be already closed, by this eliminating the leakedge current? Please note, I'm not asking about the well bias in standby mode, but about the "antileakedge" measures during normal operation.

2121


1600 KVA ka transformer hi aghar lt side par 800A aur voltage 420 ho to HT side ki cable ki rating keya ho gi?

2097


Single phase and threephase power calculation

2180


What is PQA???Applications........

2438


What will happened if the neutral of the (star connected secondry) Xformer disconnected? (if its Above KVA rated one)

2212


how withstand of hi-pot test outputs of transformer wire 2.5mm

2014


Why hydropower stations are preferred solution for meeting peak loads in grids?

1054