Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

why AC voltage source are generate as 50 Hz ?

4 6433

What will happen if induction motor is supplied with capacitive load?

NTPC,

1 5303

how we identify between current transformer and potential transformer without having it name plate?

L&T, TATA,

5 12638

Please give the formula for converting from 1 tr refrigeration to kw.

Bugema University,

2 4541

what is settable hystersis protection? If any body knows plz kindly post the answer..

2008

what is the formula for computing cable tray size & capacity

2121

what clearance required for 4.5 mva dry type transformer?

SPS,

1982

how to calculate lighting for a room

Coca Cola,

2 7603

How can we select suitable capacity generator for three phase load (inductive load) and how to take study analysis in 3 three phase load system ?

2106

A group of machines (wind turbines) connected with 33KV feeder and each machines are having individual VCB. The 33KV feeder connected with 110KV/33KV substation. The 33KV feeder tripped by over current at Substation and fault recorded at Substation as OC-R&Y phase. Same time the group of machines VCB tripped by over voltage, the fault recorded voltage was above 66KV by numerical Under/Over voltage relay. While grid drop time, this much of voltage hike is possible?

1 3344

method to check earthing

ECC,

5 11660

why slipring motor , at full speed run as squirrel cage motor?

1 4086

I have running 4 generator in paralel.All generators Voltages is same(470 V),KW also same (100 KW) but only No2 generator Amper is high than another generators. DG No:1,3,4 470V,100KW, 150 A DG No:2 470V,100KW,400 A

4 5447

What is the permissible value of earth resistance and as per which standard / act / rule ?

HBL Power Systems,

3 6971

The loads are connected with phase and ground then why current flow as the loads ?

1921


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

Define steady state error.

1040


What are reasond for high wattage in single phase induction motors

1842


what would u consider to be the basic purchase order information you would need to proceed with a cable inspection assignment?

1870


How to know of any cable size if there are not written on cabl?

1865


Difference between On Line capacitor and Station Type capacitor.

2005


A 3-PHASE TRANSFORMER IS USED TO STEP-DOWN THE VOLTAGE OF A 3-PHASE, 11KV FEEDER LINE. PER-PHASE TURNS RATIO IS 12.FOR A PRIMARY LINE CURRENT OF 20A, CALCULATE THE SECOUNDRY LINE VOLTAGE, LINE CURRENT AND OUTPUT KVA FOR FOLLOWING.A)STAR- DELTA.B)DELTA-DELTA.

3002


Classify milling machines.

1087


why we are not giving the zone 1 trip command to the master trip relay

1705


what is the meaning of 0.5ohm Resistance

1816


how to calculate transformer turn primary & secondary side 11kv to 420v

2155


describe the fully control circuit diagram of ac drives

1798


If a high resistance fault occurs,then what are the changes will happen in the system?

1411


Why we specify TNC switch with 1NO 1NC ,2NO 2NC ? how we get connection.?

1735


design of IGBT firing circuit for 11KV

2590


Why does inductive loads consume KVARs?

2017