Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

what is the acceptable earth resistance value ?

4 17731

mounting of bucholz relay engle on transformer

4 5706

Is there any reason that a vertical motor can not be mounted horizontally ? I happen to have one and would like to use it horizontally to save money by not buying a new horizontal motor.

1 3316

is there any chance to get shock from the transformer oil at the time of maintenance due to its dielectric property. . ?

Bhel,

6 8245

What is the main application of DUMMY COIL in machines?

IES,

3 15207

what is the healthy specific gravity of lead acid battery used in DG sets ?

Bhushan Power Steel,

3 7511

in underground cables, we have a grading method called 'capacitance grading' why is it called 'capacotance grading' although we do not use any capacitor in it?

1 5240

what do you mean by PF correction. A motor is rated at 15 kw,415 volts, 0.7 pf and eff of 0.92. The powerfactor is improved to 0.98 by adding capacitors at the bus. calculate the current drawn by motor under full load condition before and after pf correction

5 7310

I have 90KW Motor 60 Hz,380V Pf 0,88. after testing the Motor without Load is the no load Current 36 A,but wenn i put load after 2 hours the current increase more than 156 A. Can anybode tell me waht is the Problem?

ABB,

4 7187

SUPPOSE A CIRCUIT BREAKER HAS TRIPPED THE THE LINE WHEN A FAULT OCCUR ON IT.NOW WHEN THE FAULT HAS BEEN CLEARED, HOW THE CIRCUIT BREAKER WILL CLOSE AUTOMATICALLY NOT MANUALLY.

Bureau of Energy Efficiency, DVC,

6 8768

what is the best method of grounding in 30 MW generator?

1983

how to calculate fault level?

Mylan,

2225

WHAT IS AIR GAP VALUE IN MM FOR A 11KV BUSHING OF 11KV/440V DISTRIBUTION TRANSFORMER. AND AIR GAP VALUE OF 25 KV BUSHING OF AT TRANSFORMER OF 25 KV TRACTION. WHAT IS THE CALCULATION FOR THE AIR GAP PERMITTED FOR BUSHINGS AT DIFFERENT VOLTAGES.

3442

1 Kva = How many HP

9 100323

1 Kva = How many KW

Reliance,

3 8643


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

what is servo motor and how to work it.

1872


what is earth pit , how we can measured it, what earth rods reference

2554


what is the difference between skin effect

2222


how to CHECK CT AND PT AT THE FAULT OCCUR IN GENERATOR RELAY PANEL .

2247


Why is back emf used for a DC motor? Highlight its significance.

1148


working of diesel generator ?

1800


what is the constructional difference between a power transformer and potentian transformer?

1711


How to set a Zone 1 distance relay for distribution feeder?

1970


Why we specify TNC switch with 1NO 1NC ,2NO 2NC ? how we get connection.?

1736


what is the concept of directional power?

1968


Explain what is use of lockout relay in ht voltage?

1037


How good are you in resolving the commercial issues to Employer's advantage?

2317


where solid grounding and where grounding through ngr done and why?

2528


What is the type of earth fault protection used in battery? explain.

2251


What is big transformer parts and their function ? Ty

2151