Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

How much pf maintan in dg set in 6o% load,when Dg runnig Neutaal Earthing removed what happen.

1972

why use in & out Diesel line in dg set.

NHPC,

1 2714

what is parellel power factor correction?

HCL,

2 4396

What is the name of transformers oil filteration equipment?

Reliance,

2089

I If i have 2kv ups in which 38Amp *8battries hou many hour's back up i get from 600Watts

2 5509

When we change the tap position of 10MVA transformer it suddenly tripped with Out of step indication and also with Static differential relay indication, Transformer Bucholz relay indn and Low oil level indication. Before 1 week the same problem occured by changing the tap position. but at that time only oltc bucholz relay activated. After testing the TxR Relay team & PET team cant find any solid reason. The values are ok also. So plz answer wat's the reason for this incident? anybody plz help.

3 7356

There is 3phase power cable from 1 point to the other point which is 100m away. Two point equipped with power meter and recorded 1st point is 205kW while the 2nd is 202kW and each phase average carry 400amps. To calculate the resistance of the 3phase power cable, is the formula using will be P=I2R?

3 5073

how does an open delta transformer works

2 5071

Difference between HRG and NGR. Are they both the same thing

4291

what happens when we apply dc to a transformer

Siemens,

7 11152

What is mean by Sensitive Earth fault & what are the effects

Enteg Technologies,

1 4529

Why pmg used in electrical generators for excitation.is there any other method without pmg ?

1 3808

I have current, kva How can calculate kv?

3 6680

how to check 3phase motor winding with help of multimeter?

2 6925

why motor run slow speed in star connection?explain how?

3 12905


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

How relay works, reverse relay, master relay, os relay, earth fault relay and what is its setting point

1806


How each of the following losses occur in d.c machines (i) copper (2)core (3) windage (4)friction please help me

2036


how much UPS neutral erath leakage current.

3730


What range of speed can you get with the armature control method of speed control of d.c. Shunt motor?

1129


In 11/0.414 KV Parralel supply network with Bus tie closed what will be the fault level is it doubled or halved??

2075


What is difference between mcb and mccb.

1149


Vaccum circuit breaker

1390


write down the formula of cable size in RM if current is 50Amp.

1341


Hello Guys !! i want to rrb section engineer electrical(signal) previous model papers? any body help me?

1904


why we are using earth pit in sub stations.?

2167


How do we calculate the Out put voltage of generator, after the excitation is being given?

1930


I WANT HOW CALCULATE TO CABLE FOR WELDING PLANT ?

1832


How to design a Unit auxiliary transformer for a power house having a unit of 65 MW and Generating voltage of 11 KV and Secondary voltage of 433V

2137


please anybody help me to find out the BHEL trainee Exam previous year questions papers . if u ve pls. send it to surekhared@gmail.com

1969


How Can I calculate for the photometrics requirements for a street lighting? Data given are: 45 units of 6 meter light pole with 150 watts metal halide lamp, 220 volts and installed in a promenade area.

2095