Electrical Engineering Interview Questions
Questions Answers Views Company eMail

How do you reset circuit breaker?

Bhel, Kaveri Steels,

1 2487

hi frnds...pls send me aptransco previous papers .....pls..pls,,,(madhar.rocking@gmail.com)and suggest me some websites

1688

what is the principal of starting of a three phase induction motor.

Moser Baer,

2 5102

Please describe HT and LT?

1 3051

what is meaning of Power factor?????????

3 8028

different between electrical and electronics Engineering????

4 5495

What is the correct procedure to shutdown VCB in 11kv substation.safety and work procedure

EGA,

3 16243

when we conduct high voltage testing why milli amp. is required?

2 3795

Please specify the parts of VCB&ACB

1 3845

I want to know what is the short circuit level when 8 NOS 2000 kVA, 415v, 50hZ generator connected in paraller

1 3793

Why the frequency of ac in india is 50 hz but in some other countries it is 60 hz.

BARC, Fedco, Qasco,

1682

What will happen to the speed of synchronous machine subjected beyond the pull out torque? Are the behavior shown by rotor remains same for both the alternator and motor?

1 3438

why the efficiency of the dc machine is high ,when it is operated as a generator?

3 5406

I find that underground strip-armoiured,4core,LT PVC cables in an earthed power distribution sytem are occasionly found in charred condition-with no trace of it except ash. Is this because of no proper earth connection/continuity (giving rising to high armour resistance)in the joint enroute or because of insufficient capability (again due to high armour resistance)of cable-armour to carry fault current or due to neglected /unprotected overloading of the cable or due to high armour currents caused by power thefts where only phase(s) are unauthorisely tapped & at the point of poer consumption earth terminal is established by burring underground a not so good earthing rod (or using an underground water pipe for the purpose)

1 3353

Why do we mix soda with water in LRS?

1 7205


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

How can I known multiplying factor .without multiplying table

1344


we have one oven for 12 zone we are installed ir lamp in oven we control load from thyrister and 0 to 5vdc so our zone no 8 getting bright in fraction of second so what we do.. Please answer

1293


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1305


What is transformation ratio what it describes?

1160


WHAT IS THE TECHNICAL SPECIFICATION OF C CURVE & D CURVE LEGRAND MAKE MCB

2072






Determine a suitable number of slors and conductors per slot for the starter 1 winding of a 3 phase, 3300 V. SO Hz 300 rpm alternator. The diameter is 2.3 m

2330


rajha power sector details

1533


size of condotory fron voltage level

1714


IN dc capacitive reactance is??

920


What current position are you holding in your current company?

1611


how can we find thae value of capacitor for single phase motor. what is difference between starting capacitor and running capacitor.

1875


I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.

1640


how to ctrl motor by use of ac or dc drive.plz explain evdintly

1473


what is the defination of Cable database? What are the points are considered while preparing cable database? Is there any sample available for cable database?

1416


please send me latest & previous years question papers for IOCL Technical level questions

1403