2132What is the correct procedure to shutdown VCB in 11kv substation.safety and work procedure
EGA,
3 18800I want to know what is the short circuit level when 8 NOS 2000 kVA, 415v, 50hZ generator connected in paraller
1 4418What will happen to the speed of synchronous machine subjected beyond the pull out torque? Are the behavior shown by rotor remains same for both the alternator and motor?
1 4283I find that underground strip-armoiured,4core,LT PVC cables in an earthed power distribution sytem are occasionly found in charred condition-with no trace of it except ash. Is this because of no proper earth connection/continuity (giving rising to high armour resistance)in the joint enroute or because of insufficient capability (again due to high armour resistance)of cable-armour to carry fault current or due to neglected /unprotected overloading of the cable or due to high armour currents caused by power thefts where only phase(s) are unauthorisely tapped & at the point of poer consumption earth terminal is established by burring underground a not so good earthing rod (or using an underground water pipe for the purpose)
1 4099Post New Electrical Engineering Questions
Tell me in detail about c.t. And p.t. ?
what is the minimum pay scale for electrical engineer (building construction)in kuwait? plz revert back with yrs of experience & pay scale respectively.
How we can come to know the substation range,without go through any name plate ?
What is slope...? Explain slope 1 and slope 2...?
Where is the best place to mount distribution panel in a house.
hi can anyone pls tell me the eee interview core questions asked in l&t
WHY EARTHING NOT NEEDED IN BATTERY IN SUBSTATION
what is smart grid? why we use it? explain in detals bcoz i want give presentatin from it....
why 5kW motor becomes unbalance if its relay trip 1st time and its set value is 7.0 A
1.Can we use 6.6/11KV 300sq mm xlpe 3core cable for LT use (415 Volt). 2. If we use it for LT then what is the current rating
Dear sir, iam completed iti ncvt electrician 2000-2002 & diploma electrical eng completed 2008-2010 distance education in rvd university, still i got B licences only but my working company want C licences, how to i get c licencese pls reply me iam in critical situation thank you karthick 9841637803
What are the basic elements used for modeling mechanical rotational system?
what is the transformer rush current?
What is ST and specify its range of voltage.
You are of electrical field and you are going for software? Why