suppose there is afault in transmission line connected to a generating station, then what r the adjustments u will take to without loss of synchronism?????
NTPC,
2 3575What is the reasonable voltage between Neutral & Earth of an electrical system for good earthing?
HAL,
6 9189What is the general power consumption rating of CPU CRT type and Flat type, Monitor,Printer, projector, Scanner?
HAL,
1206What is the current carrying capacity of 0SWG,3SWG,10 & 12 SWG solid bare overhead copper conductors?
HAL,
2724during parallel operation of two ac generator which condition must match before taking both parallel i.e speed /voltage rating /kva/exciation
2 7897IF i have switchgear with busbar current rating of 1000Amp 35kA then is it necessary to have outgoing breaker kA rating to be equal to busbar kA rating?
L&T,
6 11381Post New Electrical Engineering Questions
give some advantages and disadvantages of combiniing the session, presentation, and application layer in the osi model into one single application layer in the internet model
What is the form name of 'c' license, I want to download in web
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes
explain different losses in a transformer.
what is the relationship between current&voltage in practical purpose ?
what is the formula to calculate voltage drop/loss on 66KV Transmission Line?
How to test the vector group of a Yd11 transformer? what are the relations to be checked between various vectors to confirm this vector group?
When we have earthing mesh or underground earthing network in industrial plants, weather we have NT-S or NT-C-S kind of earthing system, so eventually weather we must use 4 or 5 wire in 400 volt level (For example 3×150+70 mm2 or 5×150 mm2) in this connection I would like to know exactly the paragraph of IEC or IEEE number
Dyn1 transformer vector group testing how to do
What is the basis for framing the rules of block diagram reduction technique?
how to increase senstivity of ct
Advantages/Disadvantages of earthing of neutral bus on MSB instead of separate neutral earthing for transformer/DG sets feeding to MSB
what ispositive, negative, zero sequence impedence?
what is the effect of power factor of machines in starting current
why do we measure VIBRATION in -24vdc and why we adjust gap voltage -9vdc to 10-vdc? i am trying to get this information since 5 years, yet i haven't get reliable answer, i hope i can get from you.