Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

I have 480V Single phase and I am trying to figure how big of a transformer (KVA's) and Primary breaker size I need to provide 200 Amps at 240V for a building.

Wipro,

1 2772

what will happen when power factor is leading in distribution of power?

AMET, JTO, Power Grid,

10 23541

In CDG type IDMTL realy O/L , E/F, O/C which are used for out going feedrs,on R-phase o/c element, Y-phase , e/f elecment and on b -phase o/c element will be connected . Why the earth fault on center phase only, why not on other two phases?

2 9347

which fault is severe and why?between lll fault and lllg fault which fault is severe and y?

GE,

2508

what happen if we give 220 volts dc supply to d bulb r tube light?

NHPC,

9 24154

suppose generator rating is 50 kw,load is 25 kw,hw much d generator ll generate?what about d remainin power?

NHPC,

2 5488

if d gen is 50kw,load is 60 kw,hw d gen ll supply d remaining power?

NHPC,

3 5439

What is the significance of vector grouping in Power Transformers??

3 6960

how we do Vector group ,magnetic balance and tap changer test in Transformer?

Afcons, BSL, HPL,

2471

which type of motor is suitable for water suction pump ?

4 6359

WHAT IS THE DIFFRENCE BETWEEN EARTHED AND UNEARTHED CABLE (XLPE)?

Essar,

6 34611

for 5KW resistive load can anyone please suggest me whether to go for UPS/Inverter or Generator depending upon cost calulations

2087

Define motor & pump?

3 11542

I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?

1872

why we not connect the 12 V batteries in parallel to get the more backup supply for an UPS ? wheter off line or on line UPS ?

2 4796


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

what is difference between earthingpits,earthing grid & earthing mess?

2513


being an electrical engineer why you wanna come into software i have an very good academics what answer i have to give

1915


what is the use of sdf?

2098


what is the constructional difference between a power transformer and potentian transformer?

1762


what is feed back and what are feed back amplifiers?

1075


what is the minimum recommended leakage current of an earthed cable connected to the body or skid of an alternator

2055


induction 3 phase motor terminal connection

2670


what is mppt (maximum power point tracking ) and how they used in solar power generation ??? what are the main components used in mppt?????

3327


What are the parts in a inverter?

2092


if the load is 80 amp for main fuse and 100 amp for breaker so how can we calculate the cable size (cooper ) .

2075


how to compute kvar in substation feeder to improve power factor and sending voltage

2140


following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?

2061


How to calculate energy stored in a capacitance

1169


what is the reqirred voltage in HT motor to get full RPM on no load test?

2069


Draw the vector diagramme for Asynchronous Induction Generator at noload,half load and fullload.