How to calculate the quantity of steam lost due to pinhole leak in a steam line of known pressure and line size?
CPCL,
1 6917how caculate the pump head to maintain perticuler pressure of water and what would be the motor size in hp for the same?
1 3379what should be the megger test report for 11KV cable when meggered with 5KV megger , what is the resistance value we should get
7 14859
How are vessel lined with glass or how are they coated?
How we can check the 2 wire proxy switch? & how it is connected to DI MODULE OF PLC?
What are the faults that might happen in SCADA ?
33kv substation lay out details & line to line & line to earth measurements
What is instrumentation technologists and mechanics?
I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.
What is the type of earth fault protection used in battery? explain.
What are the basic & Majour problems in UPS ?
how we calculate the grade of the Bituminous materials.?????
pls suggest suitable MOC of diaphragm for pressure measurement of UREA grade solution service fluid.
As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?
What are the advantages of skewing of cage rotor conductors?
Which architectural movement is also known as jazz moderna?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
What are the advantages of integrated circuits?