Engineering Interview Questions
Questions Answers Views Company eMail

What would happen if the suction pressure is low in a boiler feed water pump?

CPCL, Kelvin Power Station,

7 16311

How to calculate the quantity of steam lost due to pinhole leak in a steam line of known pressure and line size?

CPCL,

1 6917

What is meant by surging in compressors?

CPCL,

5 10302

what is the purpose of knockout drum in SRU?

3 7402

what is your ideal job?

Reliance,

1825

what current is taken from a double wound 500kva transformer

4 5514

what is the tolerance for the magnetic balance test conducted on the distribution transformer?

2516

i cannot go to my computer to set up why?

1390

What is the use of Thumb instructions in ARM processor ?

ARM, Qualcomm,

4 18415

what is the differn bitween RCCB &MCB

3 6674

what are radio collars?

1758

what is b checks and m checks in diesel generator maintenance?

1 2275

how caculate the pump head to maintain perticuler pressure of water and what would be the motor size in hp for the same?

1 3379

what should be the megger test report for 11KV cable when meggered with 5KV megger , what is the resistance value we should get

7 14859

why the crystal frequency of 8051 is divide by 12 for its working?

4 17573


Un-Answered Questions { Engineering }

How are vessel lined with glass or how are they coated?

626


How we can check the 2 wire proxy switch? & how it is connected to DI MODULE OF PLC?

2019


What are the faults that might happen in SCADA ?

1880


33kv substation lay out details & line to line & line to earth measurements

2170


What is instrumentation technologists and mechanics?

581






I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.

1652


What is the type of earth fault protection used in battery? explain.

1863


What are the basic & Majour problems in UPS ?

1605


how we calculate the grade of the Bituminous materials.?????

1829


pls suggest suitable MOC of diaphragm for pressure measurement of UREA grade solution service fluid.

2668


As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?

1199


What are the advantages of skewing of cage rotor conductors?

713


Which architectural movement is also known as jazz moderna?

840


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1369


What are the advantages of integrated circuits?

617