Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Analytical Chemistry Interview Questions
Questions Answers Views Company eMail

how can you determine a compound acidic or basic?

Celon Labs, Cipla,

2 10864

For LOD and LOQ determination which method is accurate? (slopemethod or s/n ratio method)

Reddy Labs,

4 11757

how to develop the shorter run time for pharmacopeial methods having 100 min run time?

Reddy Labs,

3 11272

How you start the method development of unknown compound.

1 5981

How to determine water content of bis tetrazole amine mono ammonium salt

3531

Is there any difference in principal of reverse phase and normal phase chromatography? and why? Please update. Thank and regard

MSN Pharma,

3 11464

How to use RF and rrf in Rs calculation( either multiply or divide)?

Micro Labs,

4 13973

WHY KBr is used in IR Spectroscopy

GVK,

3 13990

How can you prepare 0.05M Ammonium acetate volumetric solution?

2 25233

Why using 0.5% acetone in methanol mobile phase for HPLC Gradient performance check.

DRL,

2 13765

IF WE INCREASE FLOW RATE RT DECRESE.WHY

2 10745

in hplc calibration injector linearity pass,it means inj and det is good. why to perform detector linearity is it required, if it is required,what is difference between injector and detector linearity in hplc calibration

Dr Reddys, Hetero,

4 16091

how can you decide API molucule acedic or basic compound by test?

Posh Chemicals,

2 10257

acceptance criteria for lod & loq by standard deviation of response and slope??

2643

various methos to calculate precision in validation methods in HPLC?

2 7669


Post New Analytical Chemistry Questions

Un-Answered Questions { Analytical Chemistry }

Why a1% value is used for some product ? What is the criteria for selection a1% value ?

2396


What is the difference between purge septum flow and column flow in gas chromatography?

2648


some product having water content method with pyridine and ethylene glycol mixture instead of methanol? how they are selecting and methanol is not suitable solvent how ?

2705


If inhouse hplc related substance method is completly diffrent from Usp for finished proďuct with diffrent impurities then how require to prove method equivalecy?

821


what type of question will ask in the interview of lab chemist.

3365


why require to add enzymes in capsules dissolution only? is it require to tablet also?

727


Why Ethanol is Used for Standardization of GC Head space?

4273


which batch require to use for analytical method validation?

860


what is the acceptance criteria for enteric coated tablets in 0.1n hcl validation in each parameter?

947


what is mean by nitrosamine impurities?

1118


What is the diference between residual solvents and organic volatile matter

2112


How would you decide dissolution medium for NCE compound of class I drug

2315


why holium oxide prepared in 10% HCLO4 SOLUTION

1498


acceptance criteria for lod & loq by standard deviation of response and slope??

2643


How do we fix the sample concentaryion in hplc method development?

1187