Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

Difference between ultrasonic flow meter and radar type flow meter

Dodsal, Qatar Petroleums,

2 14446

WHAT IS A SYMPTOM OF FAULT WITH THE SPAN OF AN INSTRUMENT? 1)ZERO-POINT AND 100% ARE CORRECT BUT NOT A MID-RANGE. 2)ZERO-POINT IS CORRECT ,BUT 1005 INPUT IS NOT GIVING 100% OUTPUT. 3)LINEARITY PRBS. 4)1005 O/p IS CORRECT BUT ZEO POINT IS WRONG.

Reliance,

1 12128

Can a pneumatic control valve work without positioner?

SMC,

4 8481

How to adjust the zero & span of a control valve from the posiitioner(MIL)?

Bhel, SMC,

1 10558

WHAT IS SELF CLEAN ELCTRODE IN MAGNETIC FLOWMETER?? WHAT DO YOU MEAN BY THIS TERM??

IOCL,

2 9539

why to use 3 wire at RTD ? what's the reason for common wire ?

4 11016

What is the use of each wire in three wire RTD

GSPC,

2549

How to convert gpm into inches of eater.I nerd formula with example so pls help me.

1 4327

Please can anybody help for control valve sizing step by step procedure?

2197

Can anybody please let me know Orifice plate sizing calculation formula and step by step procedure

2036

Pls.could any one Clarify the following with an example. 1.At What condition Close on Rise and Close on Fall Pressure Switch contacts are used. 2.If Pressure is abnormal as per set pressure,if connecting Terminal of pressure switch breaks,how the voltage extends to Relay base. 3.Are these contacts come under fail safe philasaphy.

1 4586

how to set calibration range in a DP transmitter to measure level for a closed tank and for an open tank,and also please explain me how to set calibration range for a DP flow transmitter in a line ?

CCL Products, IOCL,

1 9527

While giving Power Supply of 24 VDC to a Transmitter,why Shield Terminal is connected either at Transmitter or at ISB.Why not Shield Terminal connected at both ends.If the Reason is to avoid Noise interference,which type of noice that is interfering.Is the Noice from the 24 VDC supply terminals or from any external source.

1 5729

what is ABB DCS SYSTEM?

OMV,

2 6665

How to find out the current of two motors having same power consumption but different RPM?

2071


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

principle of dead weight tester ?

2133


how u calibrate pneumatic n motorized c/v?

2014


Whether the DI, DOs shields can be connected with Analog Input Shield Earthpit?

2055


What is motion balance principle?

1223


What is PDS and PDMS ?

2201


plz you help about Que paper of mahagenco previous your,any model paper relad to it{maharastra power genration}

2376


Why rdt and thermocouple both give different output .and one things more, how to generate  ohm or mili volt  plz mail me merajalam143545@yahoo.com

2855


tell me the field & lab calibration procedure step by step with diagram of pressure gauge, pressure switch, pressure transmitter, temperature switch, level switch, flow switch, flow transmitter, temperature transmitter, temperature indicator, flow indicator, level indicator, control valve, thermocouple, pressure indicator (digital & analogue),

2377


i want to find out iffco get test paper

13238


HI, can anybody give details about GAS TREATMENT PLANT CONSTRUCTION,as INSTRUMENTATION ENGINEER what are the responsibilites.what are the instruments mainly instrumentation engineer will deal with

2142


Hi my friends Is any one who can assist me in knowing the typical interview questions for system engineer at General Electric pty Ltd

2166


i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1522


Derive capacitance to 4-20ma conversion formula / relation in capacitance type pressure sensor?

2300


How can we use feedback signal frm rtd for monitoring and in dcs for controlling ,then which type of rtd is sutaible 2 , 3,4wire and why ?

1676


what is the reason while warning lamp is on while the engine is cranking?

2224