Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

What is the difference between Error and Offset.

1 16754

What s the exact height of installed transmitter?

1 4842

What is the reason PT speed not incresed in gas turbine?

ROC,

2455

What is the difference between sdv and bdv ?

1 18544

why we should maintain neutral earth voltage below 1V while calibration? why cant it be 1.2V or 2V

Hospira,

2500

a laways iface problem with brine level transmitter sealing diaphram a laways giving error and maximum reading i made re range and adjust with side glass but during commission it giving gap reading between it and side glass i need help from expert to explain how to calibrate it. note:dp transmitter yokogawa company

1 3990

We do have a problem in the company that is one PT connected to PlC which is mean 1 out of 1 in PLC system we do have the PAHH is 55 mbar and PALL 8 mbar with a timer of 15 sec for the PAHH the problem started when PAHH goes more than the set point which is 55 it reached up to 71 but due to timer doesn't trip . We force it and we checked everything nothing there . We replaced the transmitter problem still there the reading goes more than the 55 bar the range for transmitte is 0- 60 mbar . So we did loop check , aculaizing valve , wiring all are okay . What the possible causes for this ???

National Petrochemical Company,

2 5369

why we are using ungrounded RTD sensor and what is difference between grounded RTD and Ungrounded?

1 15055

I want to use 1/2 inch SS316 tube in my high pressure & temperature (64 kg/cm2 & 500 deg C)after condensate pot in pressure tranmistter. 1) Is it possible to use 1/2" ss316 tube in high pressure and temperature line. Tube manufacturer is local vendor. 2)On sarting the plant, We need to do system fluse that time condesate is not in the condesate pot so steam is directly contact with the tube. We have no exact calculation to know our tube is ok or nor at this time. pleae,reply.

1 5457

in rotark mov in display err msg showing how to remove the error

1 4688

what is disadvantage of field bus (ff)type of instrument

1 6790

what are different types of cables used in instrumention how to calibrate a level transmitter online ( rosemount )

1 12843

how do we commission inergen system?

1992

what are the on/off valve precaution?

Reliance,

1 7749

if RTD damage in plant, how we know?

Reliance,

5 12447


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

Explain the working of an electronic level troll.

1151


all types instrumentation questions want

2240


I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.

2043


How can you add value to this Industry if offered the job?

1655


Where are oxygen analysers installed in cfbc boilers? What are their usual readings?

1586


basic connection and principle of axial shift sensor n differential sensors in tubine describes n draw......

2421


Isometric drawings are generated during _________________ phase of a project

2131


Explain the working of rota meter.

1272


i am preparing for BARC ,so plz mail me how to prepare for BARC. ALSO IF POSIBLE SOME RELATED QUESTIONS. MY MAIL ID IS khushi_4uall2003@yahoo.co.in

3071


what step is taken for ESD ( emergency shut down) in DCS REPLY to hashimka20009@gmail.com

2369


I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?

2253


what is IEC code in cables & how to selecting cables?

1896


why we are using digital signals for I/O & how to measure this signals is getting or not ?

2043


How can we test a bently nevda 3500/42M accelerometer monitor card by simulating it with test equipment?. what king od of signal (milli volts or volts or or resistance ) we should feed in the terminals of the card?

2511


What are different types of control valves?

1669