Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


what is lead lag compensator and for wat v using that???

Answers were Sorted based on User's Feedback



what is lead lag compensator and for wat v using that???..

Answer / biswarup das

A lead-lag compensator is a component in a control system
that improves undesirable frequency response in a feedback
and control system. It is a fundamental building block in
classical control theory.

We are using it in varied discipline such as robotics,
satellite control, automobile diagnostics, laser frequency
stabilization and many more. It can also be used in digital
control.

Is This Answer Correct ?    7 Yes 2 No

what is lead lag compensator and for wat v using that???..

Answer / prabudas

Compensator is used to compensate the deficiency in the performance of plant.
A lead compensator is used to improve the transient response and the steady state response is partially improved.
A lag compensator is used to improve the steady state response and the transient response is partially improved.
If we need a better transient response we should choose lead compensator.
If we need a better steady state response we should choose lag compensator.
If we need both transient response and steady state response we should choose lead lag compensator.

Is This Answer Correct ?    2 Yes 0 No

what is lead lag compensator and for wat v using that???..

Answer / parmar.ic@gmail,com

THe lead compasator is suitable for systems having
unsatisfactory transient response but it provides only a
limited improvment in steady state response
lag compasator is suitable for systems having
unsatisfactory transisnt response but it provides only a
limited improvment in steady state response.
lead lag compensator is used in unstable system to convert
the stable system .

Is This Answer Correct ?    6 Yes 7 No

Post New Answer

More Instrumentation Interview Questions

why cant we use mV instead of mA?

12 Answers   ABB, Power Grid, Qatar Gas, USW, Visa Steel,


what is buoyancy law?

1 Answers  


dear friends, i have seen flow as the selection critriea in presure guage (bourdon tube) and i would like to know what is the relation between flow and performance of pressure guage other parameters i found in the data sheet are pressure max. 1ksc temperature max. - 50 deg c line size - 80NB operating range - 1ksc pr. guage range - 0-2 ksc thank u,

0 Answers  


how to use level tranasmitter in closed tank application.?

3 Answers   Dalkia,


Hi Friends i am going to write BARC written test by this month 20th (20-5-2008). So please if any body knows the details about this or having previous question papers pls mail me to kkumarei@gmail.com. For Suggestions give one message to 9962122264

0 Answers   PDIL,


My friend has faced this question! I don't know clearly. So please anyone give me the correct and short answer to this question? What is variable frequency drive? Types, what is star to delta? Why this arrangement necessary?

5 Answers   Asian Paints, TCS,


model question paper of instrumentation for Jindal GET 2010.plz reply sudhanshukumar08@yahoo.com

0 Answers   Jindal,


What is the basic difference between 2 Wire, 3 Wire and 4 Wire RTD

2 Answers  


what is o2 analyzer and how it measured ,what is the role of this analyzer in cfbc boiler...

0 Answers   Mittal Steel,


I want to know the questions asked in ONGC interview(after being selected in the written exam) for Instrumentation branch.Kindly help.

0 Answers  


flow transmitter range is 0 -500 mmwcc but the transmitter shows 12 ma for o mmwc instead of 4 ma ...how to solve this problem when we apply 375 mmwc it shows 16 ma

3 Answers  


What is the difference between conductive lined pipe and conductive unlined pipe? Why do we see that?

0 Answers   Process Control Technologies,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)