what is mean by short coloumn?
it is depend on the height? or dia of coloumn.?
Answers were Sorted based on User's Feedback
Answer / hemalata d m
SHORT OR LONG COLOUMN DEPENDS ON THE SLENDERNESS RATIO THAT
IS THE RATIO OF LENGTH TO RADIUS OF GYRATION. SO IT DEPENDS
ON THE LENGTH OF THE COLOUMN. IF SLENDERNESS RATIO IS LESS
THAN 12 THAEN IT IS CALLED AS A SHORT COLUMN & VICA VERSA
| Is This Answer Correct ? | 15 Yes | 2 No |
In RCC structure,The ratio of effective length to the lateral
minimum side/diameter of column should be less than 12,is
called short column.
According to Strength of Material:-The slenderness ratio
should less than 32 ,is called short column.
It is depend on both height and diameter of column.
| Is This Answer Correct ? | 7 Yes | 1 No |
Answer / s.silambarsan
if the slnderness ratio is less than 12 is short column if
it is more it is long column.
| Is This Answer Correct ? | 4 Yes | 1 No |
Answer / rohit singh
If the slenderness ratio = lex/D‹12
If the slenderness ratio =ley/b‹12
| Is This Answer Correct ? | 0 Yes | 0 No |
Answer / raghuram
SHORT OR LONG COLOUMN DEPENDS ON THE SLENDERNESS RATIO THAT
IS THE RATIO OF LENGTH TO RADIUS OF GYRATION. SO IT DEPENDS
ON THE LENGTH OF THE COLOUMN. IF SLENDERNESS RATIO IS LESS
THAN 60 THAEN IT IS CALLED AS A SHORT COLUMN.
| Is This Answer Correct ? | 9 Yes | 10 No |
Answer / d v n potharajudd
In connection with RCC structures the ratio of effctive
length to least lateral dimension (i.e Dia) is less than 12,
it is called short column.
similarly in steel structures , if slenderness ratio is
less than 120 it is short column
| Is This Answer Correct ? | 5 Yes | 6 No |
Slenderness ratio:
Ly/Lx>12
shortcolumn.
Ly/Lx<12 long column.
| Is This Answer Correct ? | 1 Yes | 4 No |
Answer / akshaya
May be the short or long column depends on the radius of
gyration. But, for me Long column are those, which are
generally failure from bending moment and material failure.
For short column are those which are failed by only material
failure.
| Is This Answer Correct ? | 1 Yes | 8 No |
what is the cover for column,beam & footing?
Why should you consider yourself fit to be hired by jindal steel.
Where are u provide laps in columns & beams?
What is the diffrence between plinth/basement and plot area
Definition of plinth beam & Uses.
how material can be calculate for brick work in 1:6
How much shuttering oil required for per m2 shuttering by 12mm ply
hi every body..i have applied for RRB section engineers CIVIL.i wanna prepare for that,so can any one suggest me some books and where can i get the syllabus for this..i would be vry greatful if any one can help in this regard
how to calculate the chair reinforcement length in slabs, footing or anywhere??
how to calculate the wind pressure
What is a projection line?
the capacity of water tank in liters if the diameter is 3m, and maximum height of water level as 1m.
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)