what is the height between the reflux pump and condenser ?
Answers were Sorted based on User's Feedback
Answer / gohil
Position of Pump - Generally at Ground Level. (Pump to meet
NPSH Requirement)
Position of Reflux Drum and Condenser depend on Type of
Pressure Control System used for column pressure control and
type of heat exchanger (condensor) i.e.partially or total
flooded.
| Is This Answer Correct ? | 4 Yes | 2 No |
Answer / kashif
I Have installed Reflux Pumps at 0.0mtrs Ground Level While
Reflux Pot is at 5.0 mtrs Level and condensors are at 13.5
mtrs Level ,its Working Satisfactory.
While in another case reflux Pot is at 5.0mtrs and
condensor is at 10.0mtrs and Reflux Pumps are at Ground
0.0mtrs Level. This column is used for Methanol
Distillation.
| Is This Answer Correct ? | 5 Yes | 4 No |
Answer / jayesh
It will depend upon height of distillation column
| Is This Answer Correct ? | 7 Yes | 11 No |
In Galvonised iron and stainsteel pipes, in which pipe friction losses will more and why ?
How can one determine the particle size distribution for a given bulk solid?
pls send me HPCL & reliance test paper for chemical engineering.....
in what way biot number is differ from nusselt number?
Explain what are the disadvantages of using gear pumps?
Please help me send me questions for HPCL written test of Chemical Branch.I will be highly thankful to u...
What chemical is used to expand air bags in such a short amount of time?
Define a solvent?
hi im appering for the written test of vizag steel plant for MT-2009.plz send me the pattern of placement paper plzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz
Heat transfer: In a steady state one dimensional conduction with no heat generation, the differential equation is d / dx (k dT / dx) = 0. Prove that T(x) = ax b, where k, a and b are constants. (b) At x = 0, T = c and at x = L, T = d. Prove that T(x) = (d - c) x / L c for boundary conditions.
CHEMICAL ENERGY BALANCE - EXAMPLE 11.2 : Calculate the cooling duty, H required to condense and cool acetone from 100 degree Celsius to 25 degree Celsius at atmospheric pressure. The heat of vaporization for acetone at its normal boiling point is 30.2 kJ / mol. The boiling point of acetone at atmospheric pressure is 56 degree Celsius. The flowrate of acetone through the condenser is 100 mol / s = N. Value of sensible heat needed to increase the temperature of acetone in liquid form from 25 to 56 degree Celsius is 4.06 kJ / mol. Value of sensible heat needed to increase the temperature of acetone in vapor form from 56 to 100 degree Celsius is 3.82 kJ / mol. Unit of H is kJ / s.
Hi, This is Naveen, plz if anybody have experience of IOCL interview, send me question.
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)