Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


sir, kindly explain to me that how to calculate volume of
torrispherical vessel which is used in pharma company
ss reactor bottom dish volume. thank u.


No Answer is Posted For this Question
Be the First to Post Answer

Post New Answer

More Chemical Engineering Interview Questions

Any books are availble to read for industrial promotional officers exam.. Syllabus : PAPER-2 : Subject (Diploma Standard) Applied Science, Engineering and Management 1. MATHEMATICS 2. PHYSICS 3. CHEMISTRY 4. INDUSTRIAL MANAGEMENT 5. INDUSTRIAL ENGINEERING 6. COMPUTER APPLICATIONS & BASICS OF DOS, WINDOWS, UNIX, DB MANAGEMENT, DTP, CONCEPTS OF E-GOVERNANCE INCLUDING E-MAIL, E-COMMERCE, INTERNET, COMPUTER VIRUSES.

3 Answers   APPSC,


what three specific job positions do u target from the company.

2 Answers   Amec Foster Wheeler, Chevron, Exxon Mobil, Petrochemicals, TCS, Texaco,


how interstage pressure of multistage compressor is calculated?

2 Answers  


We are having proplem with the persperation smell in ETT/ECHO room in our cardiac hospital.The 2 Ton of AC is not conditioning the environment. We have to use exhaust fan to through out of the room bad air. Could anyone suggest how to coup with this effectively using chemical engineering. Any permanent solution to neutralise the bad smell.The Air freshners are not doing enough instead making a bad odour.

0 Answers  


How can you quickly estimate the horsepower of a pump?

0 Answers  


CHEMICAL ENERGY BALANCE - EXAMPLE 11.2 : Calculate the cooling duty, H required to condense and cool acetone from 100 degree Celsius to 25 degree Celsius at atmospheric pressure. The heat of vaporization for acetone at its normal boiling point is 30.2 kJ / mol. The boiling point of acetone at atmospheric pressure is 56 degree Celsius. The flowrate of acetone through the condenser is 100 mol / s = N. Value of sensible heat needed to increase the temperature of acetone in liquid form from 25 to 56 degree Celsius is 4.06 kJ / mol. Value of sensible heat needed to increase the temperature of acetone in vapor form from 56 to 100 degree Celsius is 3.82 kJ / mol. Unit of H is kJ / s.

1 Answers  


Question 105 - In a rigid rotor model in quantum chemistry, the moment of inertia I is given by an Equation E as I = Ma x La x La + Mc x Lc x Lc = m x L x L, where m = (Ma x Mc) / (Ma + Mc) and L = La + Lc, m is the reduced mass, Ma is the mass of a, Mc is the mass of c, La is the radius of a from point O, Lc is the radius of c from point O. Prove by simplest method that Equation E is wrong.

1 Answers  


QUANTUM CHEMISTRY AND CHEMICAL ENGINEERING - EXAMPLE 31.2 : (a) Let | - > = 1 | x > + 0 | y >, | | > = 0 | x > + 1 | y >. Find the value of 2 | x > + 3 | y > in term of | - > and | | >. (b) Let m to be the reduced mass. Find the value of m in term of Ma and Mb where 1 / m = 1 / Ma + 1 / Mb.

1 Answers  


ACCOUNTING AND FINANCIAL ENGINEERING - EXAMPLE 34.4 : A university is enrolling new students of biochemical engineering degree. A long queue is formed during registration. Let L = rate of newcomers to a queue, m = number of clients served at a certain time, T = time in system. In M / M / 1 queue, let T = time waiting in a queue + service time, L = 2 / second, m = 3 / second. (a) Find the service time, A = 1 / m. (b) Calculate time waiting in a queue, B = A (L / m) / (1 - L / m). (c) What is the value of T?

1 Answers  


What are the steps required to design a vapor-liquid separator or flash drum?

0 Answers  


Suppose you have hot oil and cold water, what kind fluid you flow In shell side and tube side and why?

5 Answers  


What is a good source of equations for calculating discharge flowrates from accidental releases?

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)