Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


how does h2so4 prevent oxidation of mohr salt before it is titrated?



how does h2so4 prevent oxidation of mohr salt before it is titrated?..

Answer / manoj reddy

To prevent the oxidation of Fe2+ ions of Mohr's salt to Fe3+ ions.Ferrous ions of Mohr’s salt undergo hydrolysis in aqueous solution. To prevent the hydrolysis, Conc. H2SO4 needs to be added to the Mohr’s salt crystals during the preparation of its standard solution.

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

why we do the calibration of limit of stry light in hplc & uv

1 Answers   Cipla,


When you get Moisture content by KF higher than by LOD, what does this indicate?

7 Answers  


what are risk assement in the analytical qbd?

0 Answers  


why cone formation during dissolution?

0 Answers  


Ratio of Water and Acetonitrile(diluent) is not recommended to use in cleaning method validation,why?

0 Answers   Aurobindo, Reddy Labs,


what is leading peak in hplc

1 Answers   Cipla,


What is method validation in quality control

1 Answers   Alchem,


What is the meaning of Base deactivated vials

1 Answers   Sun Pharma,


Dear sir, This is R.Kadambavadani working in a pharma industry. while doing RS analysis of ibuprofen API, unknown peak eluting some times in the 0.6 Min RT. Kindly send me what is the exact reason behind that. also am using ACN the mobile phase.

1 Answers  


what is RI detector Cut-off Value

1 Answers   Mylan,


what are the guidelines for analytical method validations?

0 Answers  


why we use Dichlorobenzene.nitrobezine.t-butyldi sulhate.for calibration of gc Head space

0 Answers   Raks Pharma,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)