Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


I have one problem for masoneilan displacer type LT.I give some imformation in data shéet given for liquid level range 0 to 600 mm and sg .955 problem is 0% is ok 25%(23%) or 50%(48%)and 75%(73%) and 100% is ok this is up value and down value all ok so please halpe me

Answers were Sorted based on User's Feedback



I have one problem for masoneilan displacer type LT.I give some imformation in data shéet giv..

Answer / rijesh

i hope that your calibration liquid you using is water[sg=1]. and your service sg=0.955.if so it is give you the output as per your observation
please make your calibration sg and service sg same value.
if you using service sg =0.95 and you using water for a measurement your maximuma span will be 95% and accordingly step change will effect.

Is This Answer Correct ?    0 Yes 0 No

I have one problem for masoneilan displacer type LT.I give some imformation in data shéet giv..

Answer / muhammad nasarullah khan

Hi Dear.
As you mentioned here taht transmitter's out put 0% and 100% (SPAN) is ok, but inbetween outputs having errror. So you are facing withe " LINEARITY PROBLEM "means out put is not linear , and that always should be linear. so go to linearity section by HART communicator ,hopefully I have answered your question.Regards

Is This Answer Correct ?    2 Yes 4 No

Post New Answer

More Instrumentation Interview Questions

Calibration procedure for electro magnetic flow meter

0 Answers  


difference between span and range

3 Answers   IOCL,


what is RPI and NUT in controlnet networx. what happen if we are increase the NUT of controlnet networx?

1 Answers   Schneider,


1,why we use 4-20 ma output of all instrument qhy not use 0- 20, 2,what is the different between PLC & DCS. 3,how can we meaure maximum span of new flowmeter if not given any information.

4 Answers   Reliance,


can u guys tell me why we are using sheild in junction bos wiring ~! ?

1 Answers  


what is the responsibility of an instrument commissioning supervisor

0 Answers   Petrofac,


In split range control, we will control 2 outputs with time interval. Eg :(with 4-20 ma signal, for 4-12 ma we are operating one control instrument like valve & for 12-20ma we are operating other control instrumet (other valve). If we get a signal of 15ma to first instrument (Valve 1), what will happened to the first valve, and if we get signal above 20 ma to 2 valve what will happened ?

3 Answers  


Isometric drawings are generated during _________________ phase of a project

0 Answers  


How will you calibrate PID controller? explain with example.

0 Answers   Jacobs, Sirte Oil Company,


What is linearity of RTD over 0 to 200 degC?

1 Answers   Honeywell,


How to do calibration of magnetic flowmeter

1 Answers   Kharafi National,


basic connection and principle of axial shift sensor n differential sensors in tubine describes n draw......

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)