Why beam breadth smaller than depth

Answers were Sorted based on User's Feedback



Why beam breadth smaller than depth..

Answer / shalender kumar

beam width smaller than depth because load bears more in vertically position as compare to flat as example of simple scale when we give the load it bends but when we give load on inverted scale it has no effect..

Is This Answer Correct ?    8 Yes 0 No

Why beam breadth smaller than depth..

Answer / b.rajendhar

section modulus increase with depth

Is This Answer Correct ?    1 Yes 0 No

Why beam breadth smaller than depth..

Answer / pankaj kumar gorai

A beam is a horizontal member in a structure. So, Greater the Depth more will it take the load as MI of the section increases with depth.

Is This Answer Correct ?    0 Yes 1 No

Why beam breadth smaller than depth..

Answer / aung pai

Normally, beam width is smaller than beam depth.Because beam width is connect to slab,that why slab can support any load together with beam width.

Is This Answer Correct ?    0 Yes 2 No

Post New Answer

More Civil Engineering Interview Questions

what is the MSL?where is it located?

2 Answers   C-Tech RC Design, Era Infra Engineering, IVRCL,


What is labour ratio for construction of residential buildings

1 Answers  


Okay guys I m new here i wanna ask you that ,if i mix two three larger stones (about 20cm dia)in concrete for column or footings what actually happens, how the strength of concrete is reduced? and why it is not allowed?

3 Answers  


Deduction in length of reinforcement steel for bar bending

3 Answers   HCC, Lanco,


What is the quantit;(pratical method) of cement, sand, and gravel to be used in M25 grade of concrete for 1000 x 1000 x 1000 mm of sand (for cement please mention in kilos, and for sand and gravel please mention in cuft

1 Answers  


residential buildings,mixing of concrete,structural,construction material,site handling.

1 Answers   Saudi Aramco Shell Refinery Company SASREF,


what is water cement ratio m10,m15,m20,m25,m30,m35,m40

1 Answers   Quaid-e-Azam International Hospital,


how to calculate the steel for 450 sft slab, please tell me the solution method

1 Answers  


plz anyone can tell me how to find the volume of dome whose radius is 3.25mt , height is 1.50mt and thickness is 0.15mt.

1 Answers  


estimate quanitity of bricks(19x9x9cm without mortar), cement & sand in 10feet X 10feet wall ?

1 Answers  


What"s mean by water macadam road (WBM)?

2 Answers  


what is diffence in grade 43 & 53 of cement?

4 Answers   KFC, L&T, NICE, Puravankara,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)