I have lowered a submersible pump having 100 LPM discharge &
130 Mts. Head, 15 HP rating on borewell. After lowering 108
Meters, It is taking 39 amps & blowing the fuse. Can someone
put light what is the cause behind it ?



I have lowered a submersible pump having 100 LPM discharge & 130 Mts. Head, 15 HP rating on bo..

Answer / k.prakashchandra

I think water level is high . Reduce the discharge as the motor is overloaded . Provide a valve on the delivery pipe to control the discharge

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

What happens if the negative to earth voltage is greater than positive to earth voltage in the battery of substation?

0 Answers  


What happens if fuse is connected to neutral wire

9 Answers   HAL,


what is the voltage between nutral and earth?

2 Answers  


difference between servo motor and synchronous motor

0 Answers   Hitachi,


WHY SPEAKER OUTPUT IN WATTS??

2 Answers  






what is rocking arrangement in arc heating

0 Answers  


High speed earth switch operation with diagram

0 Answers   KSEB, L&T, Sanden Vikas, Siemens,


WHY THE COLOR OF OUTDOOR TRANSFORMER IS BLUE ONLY???

0 Answers  


As we know multiplicity factor derivation equation is as below MF = main c t ratio / main p t ratio * meter c t ratio / meter p t ratio * meter dial constant Where in digital meters for HT kwh import export now a days meter constant are calibrated already which is 1 So my question is For HT 11kv 110 v line values are as below Main c t and p t ratio are 11000 v and 110 v and 20/5 means 20 amp and 5 amp Now meter values are 11000/√3/110√3 and primary and secondary amp are displayed as -/5 amp on kwh meter so what will be the MF for this meter ?

1 Answers   NEPC,


I want to know which cable would be best to carry 125A current to a distance of 50m. Voltage is 3phase. Kindly share the formula with answer.

1 Answers   Medway Educational Consultant,


why generator is star connected ?

3 Answers   Voltech,


How to select the ratio of neutral ct? Is there any relation in between percentage impedance and neutral ct ratio ?

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)