Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


HOW TO CALIBRATE HPLC OVEN



HOW TO CALIBRATE HPLC OVEN..

Answer / srinivasreddy

the Measure column oven temperature using digital thermometer  

Is This Answer Correct ?    9 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

are there in uv lamb that is chractrestic for wavelenghth 205 nm ?????

1 Answers   Beni Suef University, Graviti Pharmaceuticals, Sri Krishna Pharmaceuticals,


What is use of LOD and LOQ in validtion and give range and in calculation why we use 3.3* LOD here why we use 3.3

2 Answers   Dr Reddys, IPCA, Reddy Labs,


why phenolpthalin gives pink colour when we titrate aganist sodium hydroxcide & phenolpthalin gives colourless titrate aganist hydrochlric acid which is un burate

1 Answers  


is there any material other than caffene to calibrate hplc detector

13 Answers   Biocon,


What is the lab normality??

3 Answers   DRL, Tagros,


iam using ph instrument lab india make.3ponit and 5point.in calibration time 3point slope will come 98.89and 96.87.that limit is 85 to 105.what basis slope will come.any calucalation between them.5point wiicome slope 99.89?why 3p0int came 2 values

1 Answers  


If mass balance is not passing in forced degradation in method validation that method is suitable or not?

1 Answers   Aurobindo, Dr Reddys, Reddy Labs, Wockhardt,


what is the meaning of ventillation in HPLC?

3 Answers   Amneal Pharmaceuticals,


why SGF media used for dissolution . What is the use of it .can we use other media of lower pH instead ot this?

1 Answers  


hi i am m.sc organic chem and complete analytical lab tech dipolma now job in qc many time ask question you in m.sc organic why job in qc please help me i can not give proper ans please tell me

3 Answers   Arch Pharmalabs, Natco,


Why we are having specification 100% above in case of assay as there is only 100% of compound?

2 Answers   MSN Pharma, Nectar Lifesciences,


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5&#61620; 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

0 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)