Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


How we get DST moisture 15.4-16.0%. what is the calculation
or method behind it.

Answers were Sorted based on User's Feedback



How we get DST moisture 15.4-16.0%. what is the calculation or method behind it...

Answer / manojmishra

The molecular formula of Di sodium Tartrate dihydrate is
C4H4O6Na2ยท2H2O and mwt is 230.08gm
Hence, the participation of water in this mwt is 36gm and
rest of 230.08-36= 194.08 is DST wt:
So, the theoritical %water content is calculated as under:

36 x 100/230.08= 15.64%

The tolerance in water may be between 15.4 to 16.0%.

Is This Answer Correct ?    60 Yes 5 No

How we get DST moisture 15.4-16.0%. what is the calculation or method behind it...

Answer / ramalingeswararao

atually Water moleculor weight 18.02 grams 2 molicules
present in it so 2*18.02
di sodium weight 230.07


that is 2*18.02/230.07=0.1566

Is This Answer Correct ?    38 Yes 1 No

Post New Answer

More Analytical Chemistry Interview Questions

What is the difference between low pressure gredient and high pressure gredient in hplc instrument?

4 Answers  


what is the method of UV cabinet CALIBRTION

2 Answers  


how we can identify the impurity is coming below loq at transfering site?

0 Answers  


why phenolpthalin gives pink colour when we titrate aganist sodium hydroxcide & phenolpthalin gives colourless titrate aganist hydrochlric acid which is un burate

1 Answers  


we calibrate HPLC once in 6 months while iam doing calibration i came to know that calibration was failed. then how can i justify that the samples analyzed on the system during this 6 months was wright? how can i forward in to the next step for those batches?

5 Answers  


How to calculate LOD & LOQ in HPLC Validation Method

14 Answers   Dr Reddys, GSK GlaxoSmithKline, Reddy Labs, Reliance, UIS,


Why should we use Potassium iodide and Hydrochloric acid during preparation of Iodine Molar solution?

1 Answers  


What is the column performance and column efficiency?

2 Answers   Reddy Labs,


how to calculate elemental impurities?

0 Answers  


How require to perform linearity as per ANVISA? What are the acceptance criteria?

0 Answers  


Why pH range is 1-14 nt more than 14???

3 Answers   IPCA, Lincoln Pharmaceuticals,


Data was integrated with RRT CONCEPT OR Overlay with SSTchrmatogram concept which is better?

1 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)