what is pneumatic control system?
Answer / bunny
A pneumatic control system is a control system consists of
pneumatic instruments.i.e,pneumatic transmitters,pneumatic
controlers,pneumatic actuators,pneumatic final control
elements etc.These instruments are working basically with
pneumatic signals(air pressure signals).Unlike an
electronic control system,which works on elecric signals
(voltage,current etc),a pneumatic controls system utilizes
air pressure signals for the communication.Tubes are used
for the transmission of these signals like wires and cables
in an electronic control system.
| Is This Answer Correct ? | 5 Yes | 0 No |
Different between control valve and mov
What is the relation between electronics & instrumentation
What the basic of communication?
What should be hight of CONTROL panel for access & OPERATION What is BIS & INDIAN STD for SAME?
what is the si unit of pressure?
6 Answers HTA Instrumentation,
What is output of Thermocouple at 25 deg c
what is Mv with respect to temprature in thermocouple
1)unmovable objects have frequency or not?if that object have frequency,how do we measure and transmit? 2)how do u measure the continuity without multimeter? 3)we put 24volt dc supply in railway track how many distance it is traveled without voltage drop?
generally for transmitter we are giving supply 24vlts?but we are getting output 4-20ma ? how it is possible? is there any operation inside the tx?pls give complete information?
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device (<ping STN0149> from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.
what about your moleg in pogrees with company
can any one explain in which term we are flow flow is it volumetric r is it mass? and y
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)