Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


differance between L1 and L7 columns

Answers were Sorted based on User's Feedback



differance between L1 and L7 columns..

Answer / sagar.deshmukh99

L1- C18 column
L7- C8 column

Is This Answer Correct ?    32 Yes 0 No

differance between L1 and L7 columns..

Answer / saravanan thangavel

L1 columns coated with octadecyl silane bonded to porous
silica, 3 to 10 µm

where L7 columns coated with ocylsiliane bonded to totally
porous microsilica particles 3 to 10 µm

Is This Answer Correct ?    18 Yes 1 No

differance between L1 and L7 columns..

Answer / satheesh kumar

USP designed LC Columns as L,L1 denotes-C18 Column,L7
denotes as C8

Is This Answer Correct ?    12 Yes 0 No

differance between L1 and L7 columns..

Answer / harsh

L1 columns coated with octadecyl silane bonded to porous
silica, 3 to 10 µm

where L7 columns coated with octylsiliane bonded to totally
porous microsilica particles 3 to 10 µm

l1 gives better resolution then l7.
l1 have more carbon loading so good for resolution

Is This Answer Correct ?    9 Yes 1 No

differance between L1 and L7 columns..

Answer / priyanka.r

According to usp code L1=C18 COLUMN
L7=C8 COLUMN

Is This Answer Correct ?    8 Yes 3 No

Post New Answer

More Analytical Chemistry Interview Questions

Why base line not start from zero in GC Chromatography analysis.

1 Answers   Orchid,


on what basis SOP's can be changed? IF mobile phase ratio is 70:30 to how much % can we change the ratio in HPLC process

7 Answers   Cipla, Ranbaxy,


How to fix the sample concentration in related substances development.

3 Answers   Novartis, Watson Pharmaceuticals,


difference between HPLC & LC-MS

9 Answers   Lambda,


What is discriminating media? How can u justify/select that which media (pH etc...)is suitable for your dissolution study of your compound?

5 Answers   Natco, SUN,


principle of AAS & its uses ?

1 Answers   Auriga,


What is the definition of RRF

2 Answers  


how much wave length of Soduim vapour lamp used in polarimeter

2 Answers   Reddy Labs, Torrent Pharma,


On which pharmacopoeia basis we can calibrate instruments like HPLC,GC,UV,DISSO,IR etc...

9 Answers   Cipla, Laurus, Micro Labs,


pharma industries oriented

0 Answers   Apex, Micro Labs, Zydus Cadila,


What is the Deference between Bulk density & Tap density ?

2 Answers   Hikma Pharmaceuticals, Neuland, Reddy Labs,


differnc btw c18 and c-8 column

3 Answers   Cipla,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)