Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


differance between L1 and L7 columns

Answers were Sorted based on User's Feedback



differance between L1 and L7 columns..

Answer / sagar.deshmukh99

L1- C18 column
L7- C8 column

Is This Answer Correct ?    32 Yes 0 No

differance between L1 and L7 columns..

Answer / saravanan thangavel

L1 columns coated with octadecyl silane bonded to porous
silica, 3 to 10 µm

where L7 columns coated with ocylsiliane bonded to totally
porous microsilica particles 3 to 10 µm

Is This Answer Correct ?    18 Yes 1 No

differance between L1 and L7 columns..

Answer / satheesh kumar

USP designed LC Columns as L,L1 denotes-C18 Column,L7
denotes as C8

Is This Answer Correct ?    12 Yes 0 No

differance between L1 and L7 columns..

Answer / harsh

L1 columns coated with octadecyl silane bonded to porous
silica, 3 to 10 µm

where L7 columns coated with octylsiliane bonded to totally
porous microsilica particles 3 to 10 µm

l1 gives better resolution then l7.
l1 have more carbon loading so good for resolution

Is This Answer Correct ?    9 Yes 1 No

differance between L1 and L7 columns..

Answer / priyanka.r

According to usp code L1=C18 COLUMN
L7=C8 COLUMN

Is This Answer Correct ?    8 Yes 3 No

Post New Answer

More Analytical Chemistry Interview Questions

if rsd failed then what require to do?

0 Answers  


How we can determine OOT limit in Stability

2 Answers   MSN Pharma,


What is similarity factor and its use in api strength?

0 Answers  


hii, i'm had a sample of 1L that gone through extraction & evaporation. i used 0.5ml of methanol for reconstitution before injecting the sample to HPLC. i made a calibration curve using a standard solution but now i'm confused about how to display the concentration i got from the sample. for ex. i got 0.2ug/ml how i'm gonna explane this is for the 1L ? please help .. i'll really appreciate it thanks

1 Answers  


Can anybody tell me how to measure Redox potential in an aerobic matrix, for e.g., soil etc.?

2 Answers  


Why do we use KMnO4 in the test of control of obsorbance ? and why do we take specific quantity i.e 57-63mg?

0 Answers   Reddy Labs, Vimta Labs,


Whya the need of Specificity to do in Analytical Method Validation ?

5 Answers   Dr Reddys,


what is difference between assay&purity&potency?

5 Answers  


What is UV cut off?

1 Answers   Sanmar,


What is NPOC method in TOC?

1 Answers   Zydus Cadila,


Why Peak Purity is not determined in GC analysis?

1 Answers   GSFC, GVK,


in gas chromatography what is the difference between gas flow rate and average linear velocity ?

0 Answers   USV,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)