how a synchronous motor is used as a resistor,capacitor and
an inductor?

Answers were Sorted based on User's Feedback



how a synchronous motor is used as a resistor,capacitor and an inductor? ..

Answer / nishant2110

If overexcited - capacitor
underexcited - inductor
normal excited - resistor

Is This Answer Correct ?    12 Yes 1 No

how a synchronous motor is used as a resistor,capacitor and an inductor? ..

Answer / nilamani umashankar jena

SYNCRONOUS MOTOR AT NOLOAD CONDITION IT BEHAVES LIKE A
CAPACITOR

AT OVER LOAD CONDITION IT BEHAVES LIKE A INDUCTOR


AT NORMAL OPERATING CONDITION,IT BEHAVES LIKE A RESISTOR
THAT IS AT NORMAL CONDITION IT OPERATES IN UNITY POWERFACTOR

Is This Answer Correct ?    1 Yes 0 No

how a synchronous motor is used as a resistor,capacitor and an inductor? ..

Answer / ilayaprabha

when the synchronous motor is run in normal condition , it will act as a inductor. it draws the lagging current from the supply.
when the synchronous motor is run under over excitation, it will act as capacitor that means it draws the leading current from the supply.
this is the key to improve the power factor.

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

Can we pass 11kv power in 1.1kV voltage grade cable.If not why?.

3 Answers  


what is the difference b/c choke and ballast?

1 Answers  


In D O l starter motor starts as a star connected ,then in star delta starter also motor initially starts as star how come star delta is preferred from dol

2 Answers  


sir i am apearing for nic exam.i dont know exam pattern.can you please send me some model papers

0 Answers  


what is the ground clearance of 400KV transmission line?

9 Answers   Power Grid, wbsedcl,






What is technical difference between ELCB & ELMCB?

3 Answers  


A 6-pole, 50 Hz, 3-phase synchronous motor and on 8-pole, 50 Hz, 3-phase slip-ring induction motor are mechanically coupled and operate on the same 3-phase, 50 Hz supply. If they are left open-circuited, then the frequency of the voltage produced across any two slip rings would be

2 Answers   L&T,


What is the accepted limit to increase the choosen transformer capacity over the load and why ?

1 Answers  


Wat wil happen if Transformer is operated at 100 HZ Frequency?

8 Answers  


Why CBCT rating is 50/1A

0 Answers  


The maximum demand of consumer is 2 kW and his daily energy consumption is 20 units. Its Load Factor is (1) 10.15% (2) 41.6 % (3) 50 % (4) 60%

2 Answers  


star delta starter contorl circuit... drawing..

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)