Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why used 0.02% v/v solution of toluene in hexane for
calibration of UV.

Answers were Sorted based on User's Feedback



Why used 0.02% v/v solution of toluene in hexane for calibration of UV...

Answer / sunil joshi (ipca)

Hexane is the no absorbance show by absorb UV radiation so that hexane used as a diluent with toluene i UV calibration at 269 & 266

Is This Answer Correct ?    4 Yes 0 No

Why used 0.02% v/v solution of toluene in hexane for calibration of UV...

Answer / m.kallappa

piz give me ans

Is This Answer Correct ?    3 Yes 1 No

Why used 0.02% v/v solution of toluene in hexane for calibration of UV...

Answer / phani kumar

It is used as reference for calculation of spectral band width.
Spectral bandwidth is the basis of establishing its ability to resolve absorption lines separated by small differences in wavelength.

Is This Answer Correct ?    0 Yes 1 No

Post New Answer

More Analytical Chemistry Interview Questions

In the isomers,enantiomers give the only physical properties present such that no chemical properties present.

0 Answers   Laurus,


What is intact assay method development.....?

0 Answers   Neon, Orchid,


which are the diffrent batches in the pharmaceuticals?

0 Answers  


what parameters we will consider while developing a HPLC method and how we confirm our HPLC method is valid?

0 Answers   DRL, Laurus,


What is use of LOD and LOQ in validtion and give range and in calculation why we use 3.3* LOD here why we use 3.3

2 Answers   Dr Reddys, IPCA, Reddy Labs,


why we are calibrating autopolarimeter with quartz control plates

1 Answers  


WHICH PRESSURE IS HIGH EITHER INJECTOR OR DETECTOR IN GAS CHROMATOGRAPHY

4 Answers   Avon Organics, Dr Reddys, Reddy Labs,


what is the difference between loss on drying in ordinary oven technique and vacuum oven technique

4 Answers   Divis Laboratories, Ranbaxy,


sop of a uv visible spectrophotometer double beam elico model

0 Answers   Sun Pharma,


Which Zone of our country like conducting of Stability studies(Accelerated & Long term stability studies)as per ICH guidelines.

4 Answers  


What is the correct way to digest milk powder to get the corrrect value of Fe and Zinc?

1 Answers  


how require to fix the linearity and accuracy cincentration range?

0 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)