Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why used 0.02% v/v solution of toluene in hexane for
calibration of UV.

Answer Posted / sunil joshi (ipca)

Hexane is the no absorbance show by absorb UV radiation so that hexane used as a diluent with toluene i UV calibration at 269 & 266

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1)What's the meaning of Absorption,give a example. 2)What's the meaning of Adsorption,give a example. 2)what is the difference between Absorption and Adsorption.

2872


why should we perform dissolution PVT calibration only by UV spectrometer, not by HPLC ?

1692


what is third integration

1961


if you have given a blank water how you analyse by general analytical techniques?

2016


In performance Check of GC Why Hexadecane Peak is Considered 

3023


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

839


Why only Copper standard is used to calibrate Atomic Absorption spectrophotometer?

2715


if your impurity coeluting with each other in that situation how require to set specification? is it acceptable?

959


if peak get problamatic then what require to do?

782


Which are the diffrent grades of api in pharma?

743


what is partion and column chromatography

2368


How much is the standard area for glc analysis

2262


why does used dry caffien in HPLC calibration?

2018


in sampling of raw material which side is pasted sampled labels

1824


Describe your field experience sample type collected,sample techniques,field measurements taken and equipment used?

2682