Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why a diode bridge is provided in vcb control circuit ?

Answers were Sorted based on User's Feedback



why a diode bridge is provided in vcb control circuit ?..

Answer / abhishek goyal

In CB mostly we have both option AC/DC SUPPLY because of
that we can use diode in circuit.
for spring charge motor we can feed both AC/DC supply (its a
Universal motor)

Is This Answer Correct ?    0 Yes 0 No

why a diode bridge is provided in vcb control circuit ?..

Answer / girish

In VCB spring charging motor will be a DC one, but control
supply is taken from 230 AC, same will be fed to Diode
bridge and then the rectified 110 Volts DC is fed to the
spring charging motor

Is This Answer Correct ?    1 Yes 3 No

Post New Answer

More Electrical Engineering Interview Questions

what will happen if field winding of Synchronous generators given ac supply

4 Answers  


Is VVVFD reduced the starting current of an induction motor?

1 Answers  


Define magnetic centre in a motor?

1 Answers  


How to find ampere on ht side for selection of cable size ???

0 Answers  


Please nybody say, weather the result of Bharat Oman is declared or not? Probable date of declare???????

0 Answers  


The temperature rise in the sys, which leads to ….. a) Increases stress& length b) increases stress but decreases length c) Decreases stress & increase length d) decrease stress & length

1 Answers   Engineers India Limited,


why power of fm is weaker than am?

1 Answers  


What are the Full Forms of TVM, MTL, CVT ?

0 Answers  


What is the loss of power of transformer 220kv/33kv,63/80mva of % imp12.05 at 80%load

0 Answers  


which type of starter is suitable for single phase motor ?

11 Answers   IOCL,


Wind mill

0 Answers   Suzlon,


What will be the impact on motor performance if a LT motor is rewound with changed motor winding data as given below:- Original winding data: total 04 wires = 02 wires of 17 SWG + 02 wires of 16.5 SWG. Changed Winding data: total 03 wires of 15.5 SWG wire size Motor rating: 160KW, 740RPM, 415V, ID FAN application. Normal Running Current = 95% of FL Current.

0 Answers   NFL,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)