Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


What are the typical values of characteristic impedences of
overhead line and underground cabel?
Why there is so much variation?



What are the typical values of characteristic impedences of overhead line and underground cabel? ..

Answer / iamdon

Characteristic impedence of overhead line=400 ohm
Characteristic impedence of underground cable=40 ohm

Characteristic impedence= Square root of (L/C).

In case of overhead lines L dominates so higher
Characteristic impedence.
In case of underground cables C dominates(conductors are
very close to each other) so lower Characteristic impedence.

Author:arbelectbit@yahoo.com


Is This Answer Correct ?    3 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

what are the particle used along with silica gel in transformer breether,explain their functions.

4 Answers   ME, Oil India,


what is the relation between the size of the machine and the frequency? (when the frequency increases the size of machine will increase,why?)

2 Answers  


what power factor should we maintain to get maximum benefits our organisation load is 10 MW? is it best to maintain the PF at .96 rather than Unity to save electricity bill?

1 Answers  


Why 11KV/440V distribution supply use for Domestic use?

3 Answers   Essar, Getco, Nissan,


How to calculate the fuse rating depend upon the DC circuit?

0 Answers  


What does Magnetic Neutral Axis

2 Answers   Eskom, Genus, Lanco,


Why the Transformer Nuetral is grounded?

10 Answers   Infosys, Khartoum Refinery,


Sir, why generating power plant operating at above 0.9 lag? detail explaination?

1 Answers   Kirloskar, L&T,


Write the force balance equation of ideal spring element.

0 Answers  


describe the Operation of induction generators from bus bars

0 Answers   AMIE,


Rules and standards of electrical control wiring ?

0 Answers  


How to calculate main incomer rating of APFC Panel ? Let's say i want to find main incomer for 11kV, 1000kVAR Panel.

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)