Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

What do you meant by slip power recovery?

PSEB,

1 8238

Give two basic sprrd control scheme of DC shunt motor.

2 6202

What are the advantages & disadvantages of a group electrive drive?

2210

What are the advantages of individual drives?

A1 Electricals, Suzlon,

1 6571

What is plugging as applied to an induction motor?

3 27907

Define heating time constant of electric motor.

3 22020

why does chattering take place in ac contactors? can it be avoided & what care does the manufacturer take to eliminate this phenomenon????

10 56301

what will happen if the bus PT fuses are accidently removed from the circuit in 6.6kV feeder?

1 5295

why is it that the HT motors & motors having very low kW rating(<1kW) have windings connected in STAR, whereas the motors having in between kW ratings have DELTA connected windings??

5 10510

which are the criterias needed to select the kind of neutral earthing(solid earthing,resistance earthing,etc.) at various voltage levels in electrical distribution?

2046

How maesure earth neutral value & how much maximum value value required in between earth & neutral.

Bellsonica, NEC,

2130

How does ELCB work when exist earth foult? and How does RCCB work when exist earth foult?

1 9308

THE 40 MW OF POWER FOR 220 V III PHASE POWER CONNECTION REQUIRES HOW MANY KVA POWEER REQUIREMENTS

Chartered Accountant,

7 11367

what is intermediate switch

1 4151

In DC generator, we use commutator, having no. of segments. Then how it is possible to get a half wave of voltage and current for half rotation of armature?

2078


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

how to calculate the surge level of surge suppressors related to the SF6 cicuit breakers?

2019


What happened ,If 3 phase clearance not maintained in 33KV Line,11KV LIne etc?

2408


sir pls tell me . our ct specifications are 120/5 ,2 core , 0.2 and 5p10 class , 30va and 30va buden. insted of 30 va i want use 15 va. can i use?

1562


Explain cos(theta) and Sin(theta)

2164


what is the difference between general inverter and solor inverter clerly explain plz

2158


how dia of wire and angles are calculated for overhead shielding wire to protect substation equipment from lightening strokes???

2090


tell me some type of questions throught which i can prepare for exam and do my best

2104


I have a situation to design sub-Distribution board/Panel meant for feeding power sockets. In the incomer CAN i Take TP MCCB with Neutral Link and All the outgoing feeders with to sockets with TP MCCB and Neutral Link? P.S : My System is IT Earthing

1879


A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.

2010


I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?

3866


When is lag lead compensator is required?

1178


how many current required for hypo test

2047


What is mathematical model of a control system?

1211


IN MY SYSTEM THERE IS ONLY OVER CURRENT EARTH FAULT RELAY IS AVAILABLE. FOR THE UNBALANCE SENSING IS THERE ANY RELAY IS AVAILABLE? THE SAME CTs WHICH ARE USED FOR THE OVER CURRENT EARTH FAULT RELAY CAN USE FOR UNBALANCE ALSO?

4228


what is mean by Digital Logic Meter (DLM)

2446