why does chattering take place in ac contactors? can it be avoided & what care does the manufacturer take to eliminate this phenomenon????
10 56301what will happen if the bus PT fuses are accidently removed from the circuit in 6.6kV feeder?
1 5295why is it that the HT motors & motors having very low kW rating(<1kW) have windings connected in STAR, whereas the motors having in between kW ratings have DELTA connected windings??
5 10510which are the criterias needed to select the kind of neutral earthing(solid earthing,resistance earthing,etc.) at various voltage levels in electrical distribution?
2046How maesure earth neutral value & how much maximum value value required in between earth & neutral.
2130THE 40 MW OF POWER FOR 220 V III PHASE POWER CONNECTION REQUIRES HOW MANY KVA POWEER REQUIREMENTS
7 11367In DC generator, we use commutator, having no. of segments. Then how it is possible to get a half wave of voltage and current for half rotation of armature?
2078Post New Electrical Engineering Questions
how to calculate the surge level of surge suppressors related to the SF6 cicuit breakers?
What happened ,If 3 phase clearance not maintained in 33KV Line,11KV LIne etc?
sir pls tell me . our ct specifications are 120/5 ,2 core , 0.2 and 5p10 class , 30va and 30va buden. insted of 30 va i want use 15 va. can i use?
Explain cos(theta) and Sin(theta)
what is the difference between general inverter and solor inverter clerly explain plz
how dia of wire and angles are calculated for overhead shielding wire to protect substation equipment from lightening strokes???
tell me some type of questions throught which i can prepare for exam and do my best
I have a situation to design sub-Distribution board/Panel meant for feeding power sockets. In the incomer CAN i Take TP MCCB with Neutral Link and All the outgoing feeders with to sockets with TP MCCB and Neutral Link? P.S : My System is IT Earthing
A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.
I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?
When is lag lead compensator is required?
how many current required for hypo test
What is mathematical model of a control system?
IN MY SYSTEM THERE IS ONLY OVER CURRENT EARTH FAULT RELAY IS AVAILABLE. FOR THE UNBALANCE SENSING IS THERE ANY RELAY IS AVAILABLE? THE SAME CTs WHICH ARE USED FOR THE OVER CURRENT EARTH FAULT RELAY CAN USE FOR UNBALANCE ALSO?
what is mean by Digital Logic Meter (DLM)