how to get 48 V DC I have ... 1. 12 volt power supply board 2. DC power supply ( max. 30 v) 3. 9 volt batteries ( 2 - not chargeble)
2 4508how long will take to burst/damage for a CT when secondary in open condition? Experienced: During switchgear testing(Primary current injection test) some of the CT are in open condition, but nothing happen's why?
1 3566i am confused about generator. i have generator of 380 KVA that is 304 KW by that formula KW=KVA*0.8... then by this formula I=KW/V*1.732*0.8 the amperes are 528.673. so that is the load which i put on one phase of generator or this is total 3 phase load on Generator.......
3 5345what is sustainable current of any conductors . a bare busbar or pvc cable has different sustainable current .
1734If we know the load for generator in KW then how it will be change to amps and also if we know the load in amps how it will change in KW and what Generator is good for that...suppose load is 500 amps 3phase......??
1 3311what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....
7 8964Post New Electrical Engineering Questions
how is the magnetic current test is different in delta-star and delta delta transformer.
Explain the working of variable frequency transformer?
how to modify DOL control panel into Delta Y connection?
What is the breaking capacity of transformer and how can we calculate the breaking capacity of tranformer
What type of DC motor would you see for a lift?
Explain the laying procedure and laying depth of submarine/subsea power cable for 220/400KV system? Also available cable diameter?
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
What is the source of dependent source ?
is it possible to say motor horsepower number without seeing name plate(when name plate damaged)
An ISP is granted a block of addresses starting with 150.80.0.0/16. The ISP wants to distribute these blocks to 2600 customers as follows. a) 200 medium size businesses; each needs 16 addresses b) 400 small businesses; each needs 8 addresses c) 2000 households; each needs 4 addresses Design the subblocks and give the slash notation for each subblock. Find out how many addresses are still available after these allocations.
Where I can get the sample question for post of Junior engineer electrical-II For RRB Bhubaneswar.
What is the direction of current flow in ct secondary...means if the current is flowing from P1 to P2 then what will be the direction of current flow in ct secondaryw
I need to connect a synchronous generator to the grid using automatic synchronization and two circuit breakers (one for synchronization, one for end connection to the grid), how to determinate the required diameter of the cables?
Difference of induction motor & servo motor ??
difference between ac series and parallel circuit