In an electrical conductor, if current flows because of flow of electrons, then why not the conductor gets thinner day by day???
1 280110Hp, 3-phase, 415v, 50Hz induction motor. The above motor is to run on Star-Delta connection, so how do i make following hardware selection 1) MCB, 2) Contactor, 3) Wire Gage (Depending on P-P current or Line Current), 4) OLR, Please tell in detail how to do the above, so as to get the ans. of it even if the Hp rating changes.
1 5506Can we use a window type neutral CT instead of a bar type neutral CT. We have an issue with a neutral bar type CT of 800/1 ratio with a Circuit breaker NS800L shneider type, and we want to change it with a window type. Pls advise. Thanks
1 2645Lt trivector meter with ring type CT.Spec of meter are 3x240 v, -/5A. Ring ct spec. are 60/5A, line voltage- IL .66/3.0KV..what is the multiplying factor
1 2933Why we Do not connect the windings of the motor in delta? & what would happen if we do that? I mean the winding themselves not the three lines that are coming to the motor?
1 2657If we connect a motor and generator together (I mean that the generator gives the motor electricity and the motor gives the generator movement) regardless the losses. Will the generator still generate and the motor still move?
1692i need list of swg(standard wire guage) or area of conductor v/s current carrying capacity of conductor copper & alluminium...
1375we have a 2.5hp Starite electric motor water pump,the elec motor burned out,we need to replace starting capacitor(old capacitor specs erased),what microfarad rating capacitor do we need? 110-125V
1340Post New Electrical Engineering Questions
After doubling voltage from solar cells & use step down voltage transformer can we get high current output with low voltage.
Which test will be more severe for VCB?
what is earthing transformer? draw the winding dia.of earthing transformer.
there are cam operated switches - why we call cam operated , What is cam ?
How many types of protection relays are there based on the characteristic?
kVA rating of ordinary transformer is increased when connected as an auto transformer because A transformation ratio increased B secondary voltage increased C energy is transferred both inductively and conductively D secondary current increased
i am completed in B.E(Electrical and Electronics Engineering) with 8 months experience in Quality Control Engineer at Bharathi Industries,Coimbatore.
What is the difference between diesel generator engine with and without turbo charger with the same capacity?
condition Autotrip facia come on control panel of electrical transmission line?
EXPLAIN THE TRANSFORMER MAINTENANCE?
how is the magnetic current test is different in delta-star and delta delta transformer.
What is main cause of cable's terminal point burned in Lug on high temperature although lug and cable selection is ok as per stantard and also tightness is ok as per situation. so please take in deep and tell correct answer thanku.
Can 33kva/415v transformer be run underground? If the answer is yes why and if the answer is no why?
how the synchronizing is obtained at bus couplers in grid substation? (because there we cannot change the frequency in one of transmission lines like in generator synchronization)
what is the minimum pay scale for electrical engineer (building construction)in kuwait? plz revert back with yrs of experience & pay scale respectively.