extremely urgent please, why a fuse is used before voltmeter but not with a ammeter connected to a CT(current transformer),thanks in anticipation.
4 10377We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
1 2215watt meter have 4 terminals what there name??? and what theses 4 terminals indicates ?? and why 2 terminals are short circuited??
1 6480what is the difference between single ratio, multiple core and multiple ratio, multiple core ? please explain.
NTPC,
1 2267why the 4 terminal are named as main, line, common, voltage (M, L, C, v) of a wattmeter?? why not its nameed as A,B,C,D??
6 46022Hi,, Just I want ask, if the power factor decrease what happen in voltage regulation? Thanks..
1 3770Post New Electrical Engineering Questions
How to do cable earhing? whether by grounding Armour to ground or by running extra G.I wire along with cable? which one is preferred mostly amoung them? If the second one is more preferable how many GI wires to be run along with cable (1 or 2)?
IF ANYONE HAVE ANY QUESTION ASK ME AT MY MAIL anmol.bhardwaj5@gmail.com
If a current -8+6sin6t is flowing three ammeter, one is a centre zero PMMC meter, one is true rms meter and one is moving iron meter. What are the reading of these three meter respectively?
i need the curve duty cycle and amper for (150 kva @50% dyty cycle) transformer turn ratio :19 and vin 400
Anybody tell me about modbus hex address of l&t trivector meter er300p??I want to read voltage,current,kwh etc via rs485...If anybody have a manual then send on my mail..Brijeshmodi18@gmail.Com
Can anybody post questions asked in Engineers India Limited Interview? Thanks in advance.
sir& friends i want the collection of recent quetions asked in interview of top most companies please send me on my email san.jsr@hotmail.com
plz tel me syllabus and exam date 4 jr executive engg (electrical)
WHAT IS THE MEANING OF BALANCED / UNBALANCED IN STABILIZER TYPES.
hi this is hema, r there any books in particular for the preparation of the APPSC-A.E.E(electrical), if so please mail me the names ... thank u .
i want bhel placement paper for electrical if anybody having pl send to my id kavitha867@myway.com immediately
What is the height of DA, DAL, DB, DC & DDE tower?
how you will decide the distance between the power transformer and its fencing
I am apply the AAI. So i want electrical sample question paper in technical with answer my id is vijayjobsmart@gmail.com
please send me previous year questions of jspl through which i could prepare myself for the test.