If a 1.5V,3W torch light bulb is connected in series with a 15HP/11.19KW,230V single phase motor and the combination is connected against a 230V supply and switched on than what will happen keeping all other parameters as it should be A)the bulb will glow normally B)the bulb will not glow C)the bulb will glow with extra brightness D)the bulb will burn out and if a fuse is connected to the above circuit will something happen to the fuse and what about the single phase motor will it be affected? Please explain with derivation
4 6875what is an unbalance in acircuit? in a three phase 3wire circuit how an unbalance will come? in a three phase four wire system how an un balance is coming?
1789IF we have 500kva transformer 11.0/0.415V, 50Hz. How to calculate the current on HT & LT side, how can we consider for its breaker (HT & LT both)? You are requested to solve the question herewith.
3 14603If I have a LT panel 3ph, 415V, 50Hz which demand load-600kw, how we can calculate its body earth strip size.
1 3745our company have 750 kva oil transformer.still we have facing a problem that is when voltage is 11.5 kv coming from HT side then LT-side voltage is 420v or above at tape 1.please give me best solution to decrease the voltage
4 6579In the UVR(Under Voltage Relay) there is a knob for the hysteresis setting. what is this setting? its threshold is given from 5% to 50%. please help me....
2 6071Post New Electrical Engineering Questions
What are the basic components of the feedback control system?
Cb closed condition if there is a tcs fail whether cb will trip or not
diff.between servo motor and ac motor
hi I have done 3 yrs diploma in electrical engg after 10+2. I have 16 years of work experience into design proposals sales and engg application development in LV/MV swithcgear and sub station automation field. I want to apply for immigration to new zealand but I am not sure whether I qualify or not since I dont have a degree. Can anyone advice? Thanks Riz
Refernce currents are to be generated using refernce cueernts how can this be done??
I am having a 1500 KVA transformer whose secondary current is 2086A and my connected load is 1000 KVA, I am having 400 KVAR APFCR for PF improvement what ratio of CT should i install in LT EB Bus to get optimum PF improvement?
what are the condition that makes hooter blow?
What is Electrical Grade Aluminum for Tubular BusBars. i am confused between 6063 and T6 or T5 and what is BS 2898 and BS 159?
How many types of oil using in H/T & L/T Oil Circuit Breakers. need Explenation ?
can we synchronize star system generators with delta system generators?
is there any phase difference occurs while primary and secondary side mutual induction occurs?
what is value of Jin transformer
Draw a SLD of DG distribution up to main LT panel?
What is meant by vector group
Explain the function and difference of Restricted earth fault, simple earth fault and sensitive earth fault with connection diagram.