Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

advantages of vvvf drives over non vvvf drives for EOT cranes

2 4688

What is Load sharing of Transformer ?

2084

If a 1.5V,3W torch light bulb is connected in series with a 15HP/11.19KW,230V single phase motor and the combination is connected against a 230V supply and switched on than what will happen keeping all other parameters as it should be A)the bulb will glow normally B)the bulb will not glow C)the bulb will glow with extra brightness D)the bulb will burn out and if a fuse is connected to the above circuit will something happen to the fuse and what about the single phase motor will it be affected? Please explain with derivation

4 7194

what is an unbalance in acircuit? in a three phase 3wire circuit how an unbalance will come? in a three phase four wire system how an un balance is coming?

1895

what is cable meggering formula for low voltage ?

2407

IF we have 500kva transformer 11.0/0.415V, 50Hz. How to calculate the current on HT & LT side, how can we consider for its breaker (HT & LT both)? You are requested to solve the question herewith.

Bhutan Power Corporation,

3 14907

If I have a LT panel 3ph, 415V, 50Hz which demand load-600kw, how we can calculate its body earth strip size.

1 3889

What is method of calculating the fault current for a MDB, 50KW, 3PH, 415V, 50HZ?

L&T,

2188

our company have 750 kva oil transformer.still we have facing a problem that is when voltage is 11.5 kv coming from HT side then LT-side voltage is 420v or above at tape 1.please give me best solution to decrease the voltage

Gannon Dunkerley,

4 6896

In the UVR(Under Voltage Relay) there is a knob for the hysteresis setting. what is this setting? its threshold is given from 5% to 50%. please help me....

2 6289

why does a dc machine has high efficiency while working as a generator than as a motor ..

2069

what is mean by dry frequency

Siemens, TCS,

2527

Whats the difference between three phase and single phase?

4 9107

what is slip ring induction motor? How it works?

1 4559

what is the transformer

6 7976


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

what is accuracy ? in any meters , coils accuracy . how can u defined that ?

2494


What is the difference between single core 2 wire and single core 3 wire system? Which application we are using this? and for What purpose we are using this?

2386


What is the basis for selecting Vk/2 or Vk/4 for REF and Differential protection of Transformer and What is the significance of magnetising current

2459


can we use engine degreaser for electrical motors?

1816


How o select the electrical fuse?.What are its characteristics.How to select the material od fuse?

2036


I Want randstand placement papers

1877


Which type of DG need Netral Earthing?

5391


WHY THE DIMENSION OF TWO SAME RATED MACHINE IS DIFFERENT ?

2291


What do you mean by an instrument transformer?

1154


in Contactor opearation Why there is a difference in the values of the operate and release voltage in case AC supply

2172


how to choose cable size with respect to load? how to convert cable size in mm2 to sq.mm?

6118


Please explain the following and how these are working with PLC unit 1.I/O Module 2.I/O Device 3.Adaptor Card 4.Ribbon Adaptor 5.RS 485-FC

1667


Different types of relay fault which phase sequence??

956


I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.

2164


What is the disadvantage in proportional controller?