The formular of how to calculate a cross sectional cable to feed an electric motor. Examle: 15KW, 26.1A, 415V. Calculate the cable size in mm2
Sona,
3 6757Can you explain the phase displacement between primary and secondary of power transformer of any vector group(for ex)?
1 2579I have two power supply.a)govt. power b)Captive power.3 phase load connected inside factory.when source change govt. source to captive some motor rotate reverse. Is phase sequence changes when if off & on?If I off generator & on it again is it possible to get changed phase sequence??
ABB,
4 5422if i have one capacitor=80 micro farad which correct the unity power factor,but i want to make capacitor bank who correct the power factor.so,how to split this capacitance value?
2 3327in breather of transformer how sillicon gel absorb the moisture?wat happen when the moisture in that oil?
1 3535sail kaott diploma ece ke interviw me qus.kis parkar ke aate hai aur G.S me kya puchate hai kya sameedyaan me kis parkar ke qu.puchate hai
Sail,
2952What motor is used in ceiling fans and what motor is used in table fan.? why table fan is costlier than ceiling fan?
Bhel,
6 26697Post New Electrical Engineering Questions
why the making current is more than then the breaking current and if its true then its about a controling circuit or breaker power contact points
if grounding is notdone at regular intervals for long distance transmission, will the load connected at distribution end receive voltage during negativehalf cycle of the sine wave?
WHAT IS LOAD CELL
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
I Need standard operation procedure(SOP)for 500kva Oil type transformer oil filtration & Procedure for IR value checking.
what is the value of combined earthing in general electrical circiut?
What are the basic components of the feedback control system?
what is doid
I FINISHED MY B.TECH IN EEE . I AM IN NEED OF A GOOD TRAINING INSTITUTE TO DO COURSES .. CAN ANYONE SUGGEST GOOD CENTRES IN TAMILNADU ,BANGALORE ,OTHER AREAS???????
some basic standard questions on transformer.
The magnitude of sum of two sinusoidal av voltage is equal to 230 volt.the magnitude of each individual voltage is also equal to 230 volt.what must be the phase difference between voltages?
Define rise time.
3- What is the target from Zero Impedance, Single Phase Imp., S/C Imp. and magnetic balance tests?
EXPLAIN THE TRANSFORMER MAINTENANCE?
I am inpecting a 10kVA UPS what tests should i do and should i observe?