For a 50MVA (138/69/13.8 KV) transformer, what would be the maximum demand in order not to exceed 80% of its operating capacity.
2 5384i want to make an elec generater with only 12v car battery car alternater and 12 volt motor ..... will the battery charge and give power at same time with out over charging the battery?
1 3680we are having 110 Kv,250mA Electrostatic precipitators for coal fired boilers. what will be static voltage and current after discharge and what time it will remain before earthing?
1908How Kneepoint voltage of CT practically related when CT in service. ie Knp is above 670 what exactly means
ABC,
1979Post New Electrical Engineering Questions
for 750 kw LT load what will be the ht kva
While converting delta into star or star into delta ,the three values of resistances remains unchanged .Find out the value?Let In star R1=x;r2=x;R3=x On converting into delta,R12=x;R23=x;R31=x Find the value of x
there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit
Explain the construction of the conservator, operation and purpose, and draw the diagram of the conservator.
Can we use shunt trip coil instead of trip coil with protection relay for protection?
hi pal, i am vengatesh from tamilnadu(chidambaram),i have called for the written test for the post of jr executive(ELECTRICAL) of AAI ,I dont know about the question paper pattern,so any kindly help me to face the examination,post me the model question papers and some tips to write my examination to (vengi.annadurai@gmail.com)
how can I calculate charging current of cable/overhead conductor? what is roll of voltage in it ?
While testing a ZCT what parameters have to check or measure?
HOW can i REuse the fused MLL LAMPS & GLS LAMPS at our factory
WHat is the general checks required for Dry type transformers
11 kv input, 66 kv input advantages
sir, what is the importance of Fault MVA. how to calculate fault mva of 33kv substation connected by 6.5 km line(single circuit with equal spacing) with 110/11kv transformer in 110kv susbstation.the fault mva on 11 kv bus in 110kv susbstation is 208mva.
In both 600/1000 V cable and 450/750 V cable, we can supply 415 V. However for distribution, all utilities are using only 600/100 V instead of 450/750 V. What is the reason?
THERMAL CAPACITANCE IS MEASURED IN..................................................
For high frequency application we use which transformer?