what will be the minimum megger value for 132 Kv (earthed) potential transformer

3 7477

Why there is not any reactive power in DC although it causes magnetic field.

7 19979

we erected (48HP)63kva dist transformer and incoming from 11kv line,out going is 415v domastic line 2.04 km.for that actual output current is 84A. what are the losses and final output current.

Essar,

3 4261

how we find transformer capacity by ohm

1728

In Fluorescent tube there is a writing like 6500k . what this 6500k represents?

4 5376

For a CT the number of turns in the primary winding is.........

5 7167

Is it necessary to carry out sheath test after cable jointing? If the value is zero of such instance , is it ok to energize the cable?

1 3431

what are the differenc between vcb and sf6 breakers

Google,

7 26417

what is the preventive @ predective maintenance

2 4052

where we take earth in hill station

1 2962

how can electricity is produced without water

Bescom,

6 8517

What is the size of electrical cable to be used for a space heater single phase 240V ?

3 4386

How to calculate the total number cells required for a particular KVA UPS system?

1 3211

what are adantages of OC and SC test over the load test?

5 10051

How the field flux is controlled in DC drive ?

TATA,

4 4987


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

WHY RATING OF VCB NOT LESS THAN 630A

2018


What is the necessary and sufficient condition for stability.

696


why asa method ZPF method is more accurate than ASA method?

5305


I need bhel electrical test pattern & paper

1388


What will happen if a dc source is given to a tubelight. Will it work or wont it work....

1476






all the technical question with answers pleas send your email id ramar_eee@yahoo.com

1561


The efficiency of a 100kva transformer is 0.98 at full load as well as half load , for this transformer what is the Copper loss at full load ?

1789


following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?

1605


How Self works in DG set

1396


Define sensitivity?

651


What is Bolted fault?

1671


what r the checklist while installing 500 kva transformer

1791


What if high voltage side circuit breaker of a ehv transformer instead of lvcb? Kindly elaborate.

1310


what is the function of impulse relay

1991


oil cooled transformer

1755