Electrical Engineering Interview Questions
Questions Answers Views Company eMail

How to calculate Air conditioning capacity for a telecom BTS shelter?

3035

what is the difference between electrical degree n mechanical degree?

IGCAR,

3 58277

How to calculate Battery back up time for a 400 AH Battery bank having a load of 20 Amps and charging time required to fully charge this battery bank?

2 6965

How to calculate battery back up time for a 400 AH battery bank installed in telecom shelter for a load of 20 Amps and time taken to fully charge this battery bank?

3 20010

How to calculate the electrical load for a standard telecom BTS shelter and capacity of DG set required to cater to this load?

Bhel, INDUS, Indus Towers,

3 37671

How to calculate the Airconditioner capacity for a standard telecom BTS shelter?

3 11182

What is Negative Potential Bias

TATA,

1779

For DG set,if the loading is increased,does flue gas temperature increases or not?

NTPC,

2 5370

what is the importance of creepage distance in disc insulators

1 3827

hy i need help with LabView, I need a sample code of LabView to download serial data from the Intellivue Patient Monitor to PC. Thank you in advance.

1 4048

how electical engineer is related to apsrtc (general) post? if they ask a question in interview as why did u choose this job what shd be answer

1631

a 25kvar capacitor bank connected to the secondary side of transformer.then why the capacitor draws more current then rated

TATA,

3 6950

A 400KVA ,50HZ TRANSFORMER IS TO BE OPERATED AT 50HZ.THEN KVA RATING OF THE TRANSFORMER?.

GATE,

4 7422

A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE

IAS, TATA,

2064

why the voltage level in transmission line are in multiple of 11kV, 22kV, 33 kV etc..( i.e., 220 V )?

4 7286


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

why we r not earthed Control cable of C.T. terminals

1537


please explain how to do 'pole drop test' on generator?

2373


in wind mill use 2100 kw asychronous generator ( induction generator ) rotor voltage : 3300,stator voltage : 690, rpm : 1511 type : MRL063E04 ' we check rotor resistance magger value found following. R-EARTH - 00 M.OHM,Y-EARTH-34 M.OHM,B-EARTH- 33M.OHM R-Y: 31 M.OHM, Y-B: 00 M.OHM,B-R :33 M.OHM HOW CAN I TAKE DECISION?pls ans. quickly

1871


what kind of quetions will ask in BHEL in interview? Plz help me?

1569


how to control the speed to switched reluctance motor

1480






I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1406


What is state space method ? Why its used ? Can it applicable on linear, non-linear, 1st order, higher order, homogeneous, non-homogeneous, open-loop , closed loops , stable & unstable systems ?

1583


what is power factor ? how we can calculate the low power factor and amount of capacitor for improve that low factor ?

1079


please anybody help me to find out the BHEL trainee Exam previous year questions papers . if u ve pls. send it to surekhared@gmail.com

1501


In dc ckt. 24v or 110v, which one is more efficient and why?

1736


In ht capacitor ckt we are using LBS Panel it having isolator with fuse, one of HT fuse flash over, so what is reason behind this event.

1570


From what on-site components does the HT panel monitoring the bus-bars in a 11kV system take inputs?

1511


sir, what is the importance of Fault MVA. how to calculate fault mva of 33kv substation connected by 6.5 km line(single circuit with equal spacing) with 110/11kv transformer in 110kv susbstation.the fault mva on 11 kv bus in 110kv susbstation is 208mva.

2479


Define maximum demand?

641


Define super node?

719