IN SINGLE PH TRANSFORMER IF LEKAGE IMPEDANCE DROP IS NEGLECTED ,THE FLUX IN THE MAGNETIC CORE and the lekage flux linking a winding are a)proportional to the applied v to the winding i respectively.
1 2192what is the range of thermal overload and over current. Answer should be in percentage of current.
RMSI,
2380when two gen set runing in parallel but thay have diffrent pole pitch, then what will be happan
2095what is the reason of current flow in nutral although load is balanced (three phase equal current)
3 6327How to calculate the cable size (XLPE)for suitable to 120KW load (if Motor or heaters etc)
SSC,
4 16643WHAT WILL BE THE SPEED OF MOTOR IF NO.OF POLES ON STATOR ARE NOT EQUAL TO NO. OF POLES ON ROTOR.???
4 8087Post New Electrical Engineering Questions
IF ANYONE HAVE ANY QUESTION ASK ME AT MY MAIL anmol.bhardwaj5@gmail.com
what is thermal resistance of PVC Cable.
Enlist four components of electrive drives.
What will happened if the neutral of the (star connected secondry) Xformer disconnected? (if its Above KVA rated one)
I need bhel electrical test pattern & paper
please send me jindal previous aptitude and technical question and answer.my email id is deep_raj@live.com
I NEED RRB APTITUDE QUESTIONS AND MODEL PAPER,PLEASE SEND MY E-MAIL joo28_eee@yahoo.co.in
kindly send me 11KV MV motor differential protection procedure by primary injection method.
could anybody able 2 send me jindal steels previous papers fr electrical steam....pls send 2 my id if possible....sirisha.shaik@gmail.com
HI SIR, AM PREPARING FOR RRB FOR SECTION ENGINEER POST. PLZ SEND ME THE PREVIOUS QUESTION PAPERS AND HELP ME. I HAVE NO ENOUGH TIME MY EXAM DATE IS 22ND JUNE.... MY EMAIL ID IS nalla.amarnath@gmail.com
Why neutral point is consider as zero potential?
sir& friends i want the collection of recent quetions asked in interview of top most companies please send me on my email san.jsr@hotmail.com
please send 5yearje solved papers on my email himmatsinghnathawat@gmail.com
I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?
A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.