What willbe change in programming when we use 5/3 solenoid inplace of 5/2 in operating of a cylinder?
2018why secondary of open delta pt (two element pt) centre tap is earth what happen when this earth is removed
1 6338what is the difference between AC choke (inductor) and DC choke (inductor), working and design point of view?
2 25642i have 28/32 MVA power transformer with 11/6.6 KC voltage rating and 12%impedance.it have star connection at both side.but it have another thied winding tertiary winding.what is used of this winding. pl tell me
7 10606how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec.
1 6793three phase 180kva diesel generator can take how much load in amp and what is formula to get this?
13 61807Post New Electrical Engineering Questions
The shot circuit in any winding of transformer result? Explain
Brushes are placed at magnetically neutral axis,when brushes reach that point,the armature conductor gets shorted,but it can be seen that the dc supply is also shorted,wont that get damage? help me plz
plz send me HPCL apptitude paper.. maulik_elect@yahoo.co.in
A ray hit a smooth regular surface at an angle of 20 from the normal. Calculate : 1. The angle btw the incident and reflection ray. 2. The angle of deviation.
what is the relation between knowing of the distance between power transformer and the capacitor feeder in case of parallel operation
Why negative feedback is preferred in the control system?
In synchronization circuit what is the function of Interposing voltage transformer(IVT)and Reverse voltage transformer(RVT)
Who many reason of ignition fail ?
What is different between Circuit breaker and Isolater?
for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance
can any one suggest me the tilt angle of my solar pannel ?? or tell me how can i know the fix tilt angle of my solar pannel?? my cordinates are 31.503629,72.993164.
Why mostly the HV side of transformer has Delta?
How to Calculate The Neutral Earth flat design calculation for the Synchronised generator (Gen 1-650Kva, Gen 2-725Kva
ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?
how load of a turbo generator can be increased