after parallaing two generators current is shooting up in both the generators.for ex: load is 400 kw..after paralling and load sharing current in running gen is approx 900 amps and incoming is 750 amps which is too high when trying toshift the load current in incoming gen is coming more than 1300 amps and both getting tripped and making blackout..
3 5638We have 3 Gensets 1.500kva,2.380kva,3.250kva How can we connect in common busbar&we have variable load.
4 7430We have 5 Distribution sections with variable loads&We have 3 Gensets(500kva,380kva&250kva) our total load is between 400kva to 600kva. so how could we connect 3gensets.
1857In siemens S7-300 PLC, what is function and function block ? What is the difference between them ? When to use function and when to use function block ?
3135In siemens S7-300 PLC, what is function and function block ? What is the difference between them ? When to use function and when to use function block ?
2097Can anybody suggest me about what are all the TECHNICAL CERTIFICATIONS avilable for Electrical Engineers for working people with clear details??
1 3393Post New Electrical Engineering Questions
What is the method of estamating of cable, CB,MCB ?
Brief working principle of stabilizer,application & safety precautions
How you give clearance to a spare feeder.
What is the minimum IR value of HT/ LT cable? Pls post separetely!!!!!
Actually I have a doubt on neutral and earth.we use Ac power without taking neutral by connecting to earth,but at that time does it affects on efficiency of any electrical components or no? If yes how?
we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain
How to measure current and voltage in an ELV circuit
how can i apilly for electrical c licencese.sir,i completed B.Tech in electrical & electronics engineering in 201onot working any company
What is “pu” in ee?
What is MS-EXCELL?
Its possible to use 3core 2R of 240 sq.mm cable for 3phases & separely 50sq.mm 3core cable fully for Neutral for connection of PCC to MCC 3ph..4wire system?
how much flux density of CRNO core
State the formula for overall efficiency of thermal power station
what will happen if OLR CT in all phases are short circuted
i want to apper for apgenco or aptransco or related can any one sugest me where can i get previous papers of thouse exams