Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

Why is a plain induction motor unsuitable for wide speed control?

2238

Distinguish between neutral earthing and equipment earthing?

7 29384

whis is the formula of converting KW into HP ?

14 32156

how to calculate compresor capacity?

2136

What is the "IS" for Rising Main?

APTransco, NTPC,

1 5481

Which type of drive is advantageous AC or DC and why?

5 6835

parallel operation for tansformer which condition fill fil for that

ITC Infotech, Suzlon,

11 12981

how power trnafor from 1 point to another point in bus bar ya transmission line( voltage trnasfer from 1 point to another poin)

Suzlon,

1924

Why the wave trap is put in Y phse only in switchyard?why not in other phases?

IAG Automation, REL,

1 7669

What is switching over voltage?

MEIL,

1 6330

what should be distance between two electrical earthing pit as per i.e.e

Badve,

13 102431

1-What is the difference between absorption factor and polarization factor in insulation resistance test in transformers? and why we inject until ten minutes to get polarization factor?

1 6386

2- What are the percentages between excitation currents in phase (R, S and T) in ∆ and Ỵ connections in excitation Current test in transformers?

1967

3- What is the target from Zero Impedance, Single Phase Imp., S/C Imp. and magnetic balance tests?

1818

4-Why we measure the insulation resistance of main core and frame in spite of that must be connected with ground before energize the transformer?

3 11158


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

where was current transformer protection units used and why??

1994


What is the loss of power of transformer 220kv/33kv,63/80mva of % imp12.05 at 80%load

1798


kVA rating of ordinary transformer is increased when connected as an auto transformer because A transformation ratio increased B secondary voltage increased C energy is transferred both inductively and conductively D secondary current increased

2597


In parallel operation time both NGR’s close or not close if both close what will happen

3683


please send privious years question papers of jindal steel and power ltd.My e mail id is rajanikant.sngh@gmail.com

2059


What is rotary phase converter?

1050


Which motor connection is preferable star-delta or delta-star?

1033


Formulae for calculating the transmission line losses for different voltage levels

2127


Please brief what is sinewave

2098


what is meant by surge? what we called for high currents?

1953


sir pls send the je exam - 2008 and other model question papers..

2024


working of diesel generator ?

1797


Let me know that how i calculate the alternator sub tranciant reactance and tranciant reactance.

2588


how can we select the appropriate VCB ?

2253


Which contains in POLE ASSEMBLY of a 11KV Kirloskar-make SF6 (Model No-FP620A12)? Will u clarify with drawing?

2126