Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...



Engineering Interview Questions
Questions Answers Views Company eMail

why the discharge pressure of ID fan showing negative at fan running condition.(boiler operating condition.)

5 18607

How much current can carry the 1 sq inch super enamelled copper wire?

4 7132

What is he use of embeded systems?

2021

as we know that N=120f/P speed of an im can be controled only through changing no if poles, can we control by changing the frequncy????

JSW,

7 10672

difference between torque mode and speed mode

JSW,

4 12194

diff. between tension mode & speed mode

BSL,

2341

my 10 hp submersible pump is tripping when connected through ELCB.I have checked the megger value of the coil's with body.It was found to be 0.2mega ohm.that is leakage is there.But when connected to mccb it is not tripping.no leakage current in the motor.Is it safe to connect to mccb? what are the problem's will arise if future?also tell me in ELCB no neutral is connected to motor.than how ELCB was working?

1 6946

In split range control, we will control 2 outputs with time interval. Eg :(with 4-20 ma signal, for 4-12 ma we are operating one control instrument like valve & for 12-20ma we are operating other control instrumet (other valve). If we get a signal of 15ma to first instrument (Valve 1), what will happened to the first valve, and if we get signal above 20 ma to 2 valve what will happened ?

3 7939

i am gng to visa interview this july i have 4 backlogs gre 1010,toefl 75,pls give me the tips pls pls

2155

From where i can get cds about mechanical related subjests

2092

whatare the disadvantages occur,if the form factor of transmission will not be equal to 1.11

1866

• Tell me a bit about the capabilities of Exchange Server. • What are the different Exchange 2003 versions? • What's the main differences between Exchange 5.5 and Exchange 2000/2003? • What are the major network infrastructure for installing Exchange 2003? • What is the latest Exchange 2003 Service Pack? Name a few changes in functionality in that SP. • What are the disk considerations when installing Exchange (RAID types, locations and so on). • You got a new HP DL380 (2U) server, dual Xeon, 4GB of RAM, 7 SAS disks, 64-bit. What do you do next to install Exchange 2003? (you have AD in place) • Why not install Exchange on the same machine as a DC? • Are there any other installation considerations? • How would you prepare the AD Schema in advance before installing Exchange? • What type or permissions do you need in order to install the first Exchange server in a forest? In a domain? • How would you verify that the schema was in fact updated? • What type of memory optimization changes could you do for Exchange 2003? • How would you check your Exchange configuration settings to see if they're right? • What are the Exchange management tools? How and where can you install them? • What types of permissions are configurable for Exchange? • How can you grant access for an administrator to access all mailboxes on a specific server? • What is the Send As permission? • What other management tools are used to manage and control Exchange 2003? Name the tools you'd use. • What are Exchange Recipient types? Name 5. • You created a mailbox for a user, yet the mailbox does not appear in ESM. Why? • You wanted to change mailbox access permissions for a mailbox, yet you see the SELF permission alone on the permissions list. Why? • What are Query Based Distribution groups? • What type of groups would you use when configuring distribution groups in a multiple domain forest? • Name a few configuration options for Exchange recipients. • What's the difference between Exchange 2003 Std. and Ent. editions when related to storage options and size? • Name a few configuration options related to mailbox stores. • What are System Public Folders? Where would you find them? • How would you plan and configure Public Folder redundancy? • How can you immediately stop PF replication? • How can you prevent PF referral across slow WAN links? • What types of PF management tools might you use? • What are the differences between administrative permissions and client permissions in PF? • How can you configure PF replication from the command prompt in Exchange 2003? • What are the message hygiene options you can use natively in Exchange 2003? • What are the configuration options in IMF? • What are virtual servers? When would you use more than one? • Name some of the SMTP Virtual Server configuration options. • What is a Mail Relay? Name a few known mail relay software or hardware options. • What is a Smart Host? Where would you configure it? • What are Routing Groups? When would you use them? • What are the types of Connectors you can use in Exchange? • What is the cost option in Exchange connectors? • What is the Link State Table? How would you view it? • How would you configure mail transfer security between 2 routing groups? • What is the Routing Group Master? Who holds that role? • Explain the configuration steps required to allow Exchange 2003 to send and receive email from the Internet (consider a one-site multiple server scenario). • What is DS2MB? • What is Forms Based Authentication? • How would you configure OWA's settings on an Exchange server? • What is DSACCESS? • What are Recipient Policies? • How would you work with multiple recipient policies? • What is the "issue" with trying to remove email addresses added by recipient policies? How would you fix that? • What is the RUS? • When would you need to manually create additional RUS? • What are Address Lists? • How would you modify the filter properties of one of the default address lists? • How can you create multiple GALs and allow the users to only see the one related to them? • What is a Front End server? In what scenarios would you use one? • What type of authentication is used on the front end servers? • When would you use NLB? • How would you achieve incoming mail redundancy? • What are the 4 types of Exchange backups? • What is the Dial-Tone server scenario? • When would you use offline backup? • How do you re-install Exchange on a server that has crashed but with AD intact? • What is the dumpster? • What are the e00xxxxx.log files? • What is the e00.chk file? • What is circular logging? When would you use it? • What's the difference between online and offline defrag? • How would you know if it is time to perform an offline defrag of your Exchange stores? • How would you plan for, and perform the offline defrag? • What is the eseutil command? • What is the isinteg command? • How would you monitor Exchange's services and performance? Name 2 or 3 options. • Name all the client connection options in Exchange 2003. • What is Direct Push? What are the requirements to run it? • How would you remote wipe a PPC? • What are the issues with connecting Outlook from a remote computer to your mailbox? • How would you solve those issues? Name 2 or 3 methods • What is RPC over HTTP? What are the requirements to run it? • What is Cached Mode in OL2003/2007? • What are the benefits and "issues" when using cached mode? How would you tackle those issues? • What is S/MIME? What are the usage scenarios for S/MIME? • What are the IPSec usage scenarios for Exchange 2003? • How do you enable SSL on OWA? • What are the considerations for obtaining a digital certificate for SSL on Exchange? • Name a few 3rd-party CAs. • What do you need to consider when using a client- type AV software on an Exchange server? What are the different clustering options in Exchange 2003? Which one would you choose

3076

what is factories act?tell about factories act?

1 4627

Bus-bar is made of which material & name of mostly used material in bas-bar design ?

7 26912

How can you calculate the size of the down conductor cable for the lightning protection system. Is 70mm2 cable can replace 95mm 2 bare copper cable when the copper tape size is 25Wx3 thk mm.

5392


Un-Answered Questions { Engineering }

What should be the percentage increase in length of the dead end clamp for bus bar conductor (Hawthorn) after hydraulic pressing and what should be the applied pressure?

1942


how to stop beam concrete between column

2389


How much wastages taken in 1. cement 2. steel 3. fine aggregate 4. coarse aggregates (10mm, 20 mm)

1876


what is the difference between switch yard to residential area.and how much required it.

1776


what is the basic steps for designing an ups,inverters, and battery connections for series and parrallel connections in ups

2215


What in your opinion makes you the most suitably qualified candidate for this post of civil engineering technician?

1153


what is polity

2115


"In a four-stroke diesel engine, In what engine exhaust valve will open?"

1777


what are the advantages disadvantages of connecting high voltage block( 1:1 transformers) transformers between the turbo generators and busbars.

2107


how to calculate current carring capacity of cable and cable selection? 1) copper flexible cable 2) copper armoured cable 3) Aluminium cable

1612


Is OHNS steel is equivalent to O1 tool steel? Suppliers give OHNS material for AISI O1 STEEL telling that both are equivalent materials. Is this correct?

3030


when we design electrical schemes of 11/.415kv distribution..wen and were should we show the relays??what is the function of it?for example..we place EFR Relay CT between transformer neutral link and transformer earth.Like this what are the other type of relays we should use?why?where?Explain please..Thank you

1808


I want previous rrb enteranse exam papers in junior engineer(Signal/Tele/c&w). please send that papers to my id dkg_unnao@yahoo.com

3343


Why IR value of the (HT cable Plus synchronous motor) is less while individually having IR values in GΩ?

1805


Explain any four vegetable fibers?